Installation and Operation Instructions
Superior™ DRT2000 and DRC2000
Direct-Vent Gas Fireplaces
P/N 900004-00 Rev. G 04/2015
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900004-02.
PFS
®
USC
Models
DRT2033xxx *
DRC2033xxx *
DRT2035xxx *
DRC2035xxx *
DRT2040xxx *
DRC2040xxx *
DRT2045xxx *
DRC2045xxx *
P900004-00
* “xxx” indicates unique model identifiers. This manual covers all Superior™
DRT2000 and DRC2000 models.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with
this appliance and shall be installed for
the protection of children and other at-risk
individuals.
L’écran pare-étincelles fourni avec ce foyer réduit le
risque de brûlure en cas de contact accidentel avec la
vitre chaude et doit être installé pour la protection Des
enfants et Des personnes à risques.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d’autres gaz, sauf si une trousse de conversion est utilsée.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a neigh-
bor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death, or property damage.
AVERTISSEMENT:
RISQUED’INDENDIE OU D’EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d’entraîner des blessures graves, la mort
ou des dommages matériels.
— Ne pas entreposer ni utilizer d’essence ni d’autres
vapeurs ou liquides inflammables dans le voisin-
age de cet appareil ou de tout autre appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bâti-
ment où vous trouvez.
Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de
gaz, appelez le service des incindies.
L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualifié
ou par le fournisseur de gaz.
Report No. F13-094

Other manuals for Superior DRT2035

Questions and Answers

  • K
    Kathy PerezSep 3, 2025
    Why does my Superior DRT2035 Indoor Fireplace have poor flame and/or blue flame?
    • W
      William KnoxSep 3, 2025
      A poor or blue flame in your Superior Indoor Fireplace can be caused by a door seal that is not properly aligned, leading to gaps and air leaks. Remove and realign the door to ensure the gasket seal is fully engaged around the door frame.
  • E
    esimonSep 18, 2025
    Why does my Superior Indoor Fireplace have a poor or blue flame?
    • K
      Karen SmithSep 18, 2025
      If you're experiencing a poor flame or a blue flame in your Superior Indoor Fireplace, it could be due to the door seal not being properly aligned, causing gaps and air leaks. Remove and realign the door so the gasket seal is fully engaged around the door frame.
  • S
    srobertsonSep 16, 2025
    Why is there soot on the logs and glass of my Superior Indoor Fireplace?
    • R
      Robert LeeSep 17, 2025
      If you notice soot on the logs and glass of your Superior Indoor Fireplace, it could be due to several reasons. First, excessive flame impingement on the logs may be the cause; ensure the logs are properly positioned as detailed on Page 54. A white film may develop on the glass during the first few fires as part of the burn-in process, in that case, clean the glass after each use (AFTER THE GLASS HAS COMPLETELY COOLED). Also, check the vent restrictor setting and adjust the air shutter adjustment lever according to the instructions in this manual. Finally, make sure the air shutter is properly opened by pushing in the rod.
  • C
    Crystal WallaceSep 15, 2025
    Why does the main burner on my Superior Indoor Fireplace turn on and then go out?
    • C
      Cindy SalazarSep 15, 2025
      If the main burner on your Superior Indoor Fireplace comes on but then goes out, first check the gas supply and gas shutoff valves to ensure gas is reaching the fireplace. Also, check the control compartment for any loose wiring to the valve or ignition module (it is recommended to call a service technician). Other potential causes, which require a service technician, include the pilot flame not engulfing the sensor or an obstructed vent system.
  • B
    bhoodSep 13, 2025
    Why does my Superior Indoor Fireplace pilot/burner frequently go out?
    • K
      Kevin AlexanderSep 13, 2025
      If you're experiencing frequent pilot/burner outages with your Superior Indoor Fireplace, the pilot flame may be too low or too high, causing the pilot/valve safety to drop out. Try cleaning and/or adjusting the pilot flame to ensure maximum flame impingement on the thermocouple.
  • C
    Christopher MaddenSep 12, 2025
    What to do if nothing happens when I turn my Superior Indoor Fireplace on or off?
    • F
      Frank WallaceSep 12, 2025
      If nothing happens when you turn your Superior Indoor Fireplace ON or OFF, first check that the wall switch plate is set to REMOTE. Then, check the gas supply and gas shutoff valves to ensure gas is reaching the fireplace. Finally, check or replace the backup batteries behind the wall plate to ensure the unit is receiving power.
  • C
    Cassandra DuffySep 10, 2025
    Why won't the pilot light stay lit on my Superior Indoor Fireplace?
    • J
      James WilliamsSep 10, 2025
      If the pilot light won't stay lit on your Superior Indoor Fireplace, even after following the lighting instructions, the issue might be a defective pilot generator (thermocouple). Check that the pilot flame is properly hitting the thermocouple. Clean and/or adjust the pilot to ensure maximum flame impingement on the thermocouple. Also, make sure the connection between the valve and thermocouple is tight and secure.
  • D
    dmedinaSep 8, 2025
    What to do if the main burner doesn't light on my Superior Indoor Fireplace but the igniter is sparking?
    • C
      chelseaestradaSep 8, 2025
      If the igniter is sparking but the main burner on your Superior Indoor Fireplace isn't lighting, start by checking the gas supply and shutoff valves to ensure gas is reaching the fireplace. Then, inspect the control compartment for any loose wiring to the valve or ignition module; if you find any loose wires, call a service technician. Also, there might be air in the gas line, which would require purging (it is recommended to call a service technician). Finally, make sure the unit is receiving power by replacing the unit's battery backup.
  • M
    michaelwilsonSep 5, 2025
    What to do if the spark igniter won't light the pilot on my Superior Indoor Fireplace?
    • E
      erica12Sep 5, 2025
      If the spark igniter on your Superior Indoor Fireplace isn't lighting the pilot, there could be several reasons. First, check for a spark at the electrode and pilot. If there's no spark, and the electrode wire is properly connected, the igniter may be defective and needs replacement. If there is a spark, try lighting the pilot with a match. If it lights, the gas mixture might be off, requiring a longer purge period. If it still doesn't light, check the gap at the electrode and pilot; it should be about 1/8 inch for a strong spark. If the gap is correct, the pilot might need replacing. Also, make sure the gas supply pressure is within the limits specified on the rating plate. Finally, the pilot orifice could be plugged, so try cleaning or replacing it.
  • D
    Daniel BarberAug 21, 2025
    What to do if my Superior Indoor Fireplace spark igniter will not light pilot?
    • W
      William BryantAug 21, 2025
      If the spark igniter on your Superior Indoor Fireplace won't light the pilot, there are several potential causes. First, check for a spark at the electrode and pilot. If there's no spark and the electrode wire is properly connected, the igniter may be defective and needs replacement. If there is a spark, try lighting the pilot with a match. If it lights, the gas mixture may be off, requiring a longer purge period. If it still doesn't light, check the gap at the electrode and pilot; it should be about 1/8 inch for a strong spark. If the gap is correct, the pilot might need replacing. Also, ensure the gas supply pressure is within the limits specified on the rating plate and that the pilot orifice is clean and not plugged.

Summary

General Information

Important Safety Information

Crucial safety warnings and precautions for appliance operation and user protection.

Installation, Operation, and Maintenance Notices

Key notices regarding appliance installation, usage, and upkeep procedures.

Packaging and Introduction

Details on product packaging contents and a general overview of the fireplace.

Installation Procedures

Approved Vent Components

Specifies the required and tested vent system components for safe operation.

Codes and Standards Compliance

Outlines compliance with national safety standards and local building codes.

Manufactured Home Installation Requirements

Guidelines for installing the appliance in manufactured or mobile homes.

Location Selection and Clearances

Guidance on choosing a safe and functional location and required clearances.

Vent Termination Clearances

Vertical Vent Termination Clearances

Specifies minimum height and clearance requirements for vertical vent terminations.

Horizontal Vent Termination Clearances

Details clearance requirements for horizontal vent terminations to combustibles.

Minimum Clearances to Combustibles

Fireplace and Vent Clearances

Specifies zero clearance for fireplace sides, with exceptions for specific installations.

Installation Sequence

Framing Requirements

Instructions for constructing the fireplace framing and ensuring structural support.

Venting System Installation

Steps for selecting and installing the horizontal or vertical vent system.

Electrical and Gas Connections

Guidance on roughing in electrical supply and connecting the gas line.

Finishing Touches

Steps for optional firebox liners, logs, glass media, and glass doors.

Install the Vent Restrictor

Vent Restrictor with Vertical Terminations

Instructions for installing the vent restrictor in vertical vent runs.

Vent Restrictor with Horizontal Terminations

Guidelines for vent restrictor usage in horizontal vent runs.

Combustible Clearances

Vertical Run Clearances

Minimum clearances required for vertical vent runs to combustibles.

Horizontal;Inclined Run Clearances

Minimum clearances for horizontal or inclined vent runs to combustibles.

Install the Vent System

Install the Vertical Termination Vent System

Detailed steps for installing the vertical vent termination and related components.

Install the Horizontal Termination Vent System

Procedures for installing horizontal vent terminations through exterior walls.

Secure Flex Venting Systems

Flexible Vent Adaptor Installation

Instructions for installing the flexible vent adaptor and connecting flex pipe.

Installing Inner and Outer Flex Pipe

Steps for securely installing the inner and outer flexible vent pipes.

Complete Field Wiring

Millivolt Wiring Procedures

Wiring instructions for millivolt gas control systems.

Electronic Wiring Procedures

Wiring instructions for electronic gas control systems.

Install Optional Blower Kit

Connect the Gas Line

Verify Proper Fireplace Operation

Pilot Lighting Instructions

Procedures for lighting the pilot light for millivolt and electronic systems.

Adjust Air Shutter for Flame Appearance

Install the Hood

Reinstall the Barrier

Install Finishing Materials

Attach Safety Labels

Installation Accessories

Touch-Up Paint Kits

Kits for repairing minor scratches and discoloration on fireplace surfaces.

Forced Air Kits

Options for adding blower assemblies for forced air circulation.

Glowing Embers and Volcanic Stone

Kits for decorative media used in the fireplace firebox.

Glass Media

Decorative glass media for contemporary fireplace models.

Firebox Liner Kits

Liner kits designed to enhance the interior appearance of the firebox.

Termination Guard Kits

Guards for vent terminations to minimize exposure to hot surfaces.

Gas Conversion Kits

Installing Gas Conversion Kits

Specific procedures for converting millivolt and electronic ignition fireplaces.

OPERATION

Carbon Monoxide Poisoning Warnings

Information on symptoms and actions to take in case of carbon monoxide poisoning.

Burn-in Period and Initial Operation

Details on the initial burn-in period, odors, and glass film.

Accessing and Managing Control Compartment

Instructions for opening, closing, and removing the control compartment door.

Gas Controls and Lighting Procedures

Overview of gas controls and procedures for lighting millivolt and electronic systems.

Installing Backup Batteries

Instructions for installing batteries for electronic fireplace backup power.

Continuous Pilot Ignition Switch

Explanation of the CPI switch for intermittent vs. continuous pilot modes.

Installing Firebox Liners, Glass Media, and Logs

Procedures for installing interior components like liners, media, and logs.

Installing and Removing the Glass Door

Step-by-step guide for installing and removing the fireplace glass door.

MAINTENANCE

Venting System Inspection

Guidelines for inspecting the vent system for obstructions and damage.

Burner Flame Appearance Inspection

How to inspect burner flame patterns and ensure proper operation.

Cleaning the Glass Door

Instructions for cleaning the glass door using approved methods.

MAINTENANCE SCHEDULE

Annual Maintenance (Before Burning Season)

Tasks to be performed annually before the heating season begins.

Periodic Maintenance (After Burning Season)

Tasks to be performed periodically after the heating season concludes.

ACCESSORY COMPONENTS

Thermostatic Control Kits

Options for thermostatic and manual ON/OFF fireplace control.

ON;OFF and Timer Control Kits

Kits for timed ON/OFF operation and manual control.

LIGHTING INSTRUCTIONS

Millivolt Gas Valve Lighting

Step-by-step guide for lighting millivolt gas valves.

Electronic Gas Valve Lighting

Step-by-step guide for lighting electronic gas valves.

TROUBLESHOOTING

Troubleshooting Millivolt Systems

Common issues and solutions for millivolt fireplace systems.

Troubleshooting Electronic Systems

Common issues and solutions for electronic fireplace systems.

REPLACEMENT PARTS

Installer Replacement Parts

Catalog numbers and quantities for parts needed by installers.

WARRANTY

Warranty Coverage and Limitations

Details on warranty period, exclusions, and limitations.

How to Register a Claim

Procedures for submitting a warranty claim and contacting IHP.

Superior DRT2035 Specifications

General IconGeneral
BrandSuperior
ModelDRT2035
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals