Installation and Operation Instructions
Superior
TM
DRT3000 Series Direct-Vent Gas Fireplaces
P/N 900285-00 Rev. B 11/2014
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900285-02.
PFS
®
USC
Models
DRT3033xxx* DRT3035xxx* DRT3040xxx* DRT3045xxx*
P900285-00
* “xxx” indicates unique model identifiers.
This manual covers all Superior
TM
DRT3000 models.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with
this appliance and shall be installed for
the protection of children and other at-risk
individuals.
L’écran pare-étincelles fourni avec ce foyer réduit le
risque de brûlure en cas de contact accidentel avec la
vitre chaude et doit être installé pour la protection Des
enfants et Des personnes à risques.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d’autres gaz, sauf si une trousse de conversion est utilsée.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a neigh-
bor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the re
department.
Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death, or property damage.
AVERTISSEMENT:
RISQUED’INDENDIE OU D’EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d’entraîner des blessures graves, la mort
ou des dommages matériels.
— Ne pas entreposer ni utilizer d’essence ni d’autres
vapeurs ou liquides inflammables dans le voisin-
age de cet appareil ou de tout autre appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer d’appareil.
Ne touchez à aucan interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bâti-
ment où vous trouvez.
Sortez immédiatement de bâtiment.
Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
Si vous ne pouvez rejoindre le fournisseur de
gaz, appelez le service des incindies.
L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualifié
ou par le fournisseur de gaz.
Report No. 13-094

Questions and Answers

  • T
    thomas32Aug 22, 2025
    Why won't the main burner light on my Superior DRT3040 Indoor Fireplace even though the igniter is sparking?
    • D
      Dana AdamsAug 22, 2025
      If the igniter is sparking but the main burner won't light on your Superior Indoor Fireplace, consider the following: * Check the gas supply and gas shutoff valves to ensure gas is reaching the fireplace. * Inspect the control compartment for any loose wiring to the valve or ignition module. If you find any loose wires, call a service technician. * Purge the gas line of air. If you are not comfortable doing this, call a service technician. * Replace the unit's battery backup to ensure it is receiving sufficient power.
  • J
    Jeffrey GreeneAug 26, 2025
    What to do if nothing happens when I turn my Superior DRT3040 on or off?
    • T
      tammydavisAug 26, 2025
      If nothing happens when you turn your Superior Indoor Fireplace on or off, consider these checks: * Ensure that the wall switch plate is set to REMOTE if you are using a remote. * Check the gas supply and gas shutoff valves to confirm gas is reaching the fireplace. * Check or replace the backup batteries behind the wall plate to ensure the unit is receiving power.
  • D
    Dawn SilvaAug 28, 2025
    Why does the main burner on my Superior DRT3040 Indoor Fireplace come on and then go out?
    • L
      Lauren MooreAug 28, 2025
      If the main burner on your Superior Indoor Fireplace comes on but then goes out, the issue might be due to: * Check the gas supply and gas shutoff valves to ensure gas is reaching the fireplace. * Inspect the control compartment for any loose wiring to the valve or ignition module. If you find any loose wires, call a service technician. * Pilot flame is not engulfing the sensor, call a service technician. * Obstructed vent system, call a service technician.
  • C
    Chris ChaseAug 31, 2025
    Why does my Superior DRT3040 Indoor Fireplace pilot/burner frequently go out?
    • M
      Megan LopezSep 1, 2025
      Frequent pilot/burner outages in your Superior Indoor Fireplace can occur if the pilot flame is too low or blowing, causing the pilot/valve safety to drop out. To resolve this, clean and/or adjust the pilot flame to ensure maximum flame impingement on the thermocouple.
  • S
    Steven RojasSep 4, 2025
    What should I do if the pilot light won't stay lit on my Superior Indoor Fireplace?
    • M
      Melissa Thompson MDSep 4, 2025
      If the pilot light won't stay lit on your Superior Indoor Fireplace, it could be due to a defective pilot generator (thermocouple). Check that the pilot flame is impinging on the thermocouple. Clean and/or adjust the pilot for maximum flame impingement on the thermocouple. Also, ensure that the connection between the valve and thermocouple is tight and secure.
  • Y
    ylongSep 7, 2025
    Why is there soot on the logs and glass of my Superior DRT3040?
    • L
      Lisa BennettSep 7, 2025
      Soot on the logs and glass of your Superior Indoor Fireplace can be caused by several factors: * Excessive flame impingement on the logs. Ensure the logs are properly positioned. * Initial fireplace operation. A white film may develop during the first few uses. Clean the glass after each use (after it has completely cooled). * Improper vent restrictor setting. Adjust the air shutter adjustment lever according to the instructions in this manual to open the air shutter. * Improper air shutter opening. Open the air shutter by pushing in the rod.
  • M
    Mark PearsonSep 12, 2025
    Why is the flame poor or blue in my Superior DRT3040?
    • M
      michael43Sep 12, 2025
      A poor and/or blue flame in your Superior Indoor Fireplace may be due to a door seal that is not properly aligned, causing gaps and air leaks. Remove and realign the door so the gasket seal is fully engaged around the door frame.
  • A
    Aaron ElliottNov 14, 2025
    Why won't the spark igniter light the pilot on my Superior DRT3040 Indoor Fireplace?
    • A
      Adam VelasquezNov 14, 2025
      The spark igniter might fail to light the pilot on your Superior Indoor Fireplace due to several reasons: a defective igniter (no spark at electrode), a defective or misaligned electrode, errant gas supply pressure, or a plugged pilot orifice. * Check for a spark at the electrode and pilot. If there's no spark and the electrode wire is properly connected, replace the igniter. * If there is spark, try lighting the pilot with a match. If it lights, the gas mixture may be improper, requiring a longer purge period. If it still won't light, check the gap at the electrode and pilot; it should be 1/8 inch. If the gap is correct, replace the pilot. * Verify that the inlet gas pressure is within the limits marked on the rating plate. * Clean or replace the pilot orifice to ensure it's not ...
  • E
    Elizabeth JimenezNov 17, 2025
    What to do if pilot light is on but no gas to burner in my Superior DRT3040 Indoor Fireplace?
    • B
      Brenda MyersNov 17, 2025
      If the pilot light is burning, the valve knob is in the 'ON' position, and the burner switch is also 'ON,' but no gas is reaching the burner of your Superior Indoor Fireplace, here's what you can check: 1. Inspect the wall switch and wiring for proper connections. You can use a jumper wire across the terminals at the wall switch; if the burner then comes on, the wall switch is defective and needs replacement. If the switch is okay, proceed to the next step. Use jumper wires across the wall switch wires at the valve; if the burner comes on, the wires are faulty or the connections are bad. 2. Test the thermopile with a millivolt meter at the thermopile terminals of the gas valve. It should read a minimum of 325 millivolts with the optional wall switch in the OFF position. If the reading ...

Summary

General Information

Important Safety Information

Crucial safety instructions for appliance usage and potential hazards.

Fireplace Installation, Operation, and Maintenance Notices

General notices and warnings regarding installation and maintenance practices.

Codes and Standards

Compliance requirements with national and local safety codes for installation.

Installation

Requirements and Clearances

Installation rules for Massachusetts, cold climates, manufactured homes, and clearances.

Wall Finishes and Mantels

Guidelines for installing wall finishes, surrounds, and mantels around the fireplace.

Installation Preparation and Sequence

Steps for preparing the fireplace and the overall installation sequence.

Framing and Support

Details on constructing fireplace framing and ensuring proper support.

Vent System Installation

Procedures for determining vent setup, installing components, and routing the vent system.

Electrical and Gas Connections

Instructions for completing field wiring and connecting the gas supply line.

Flame Appearance and Adjustments

Steps for adjusting the air shutter for optimal flame appearance and managing sooting.

Final Component Installation

Instructions for installing the hood, barrier, and finishing materials.

Safety Warnings and Labels

Guidance on attaching safety-in-operation warning labels for consumer information.

Operation

Burn-in Period and Controls

Information on the initial burn-in, control compartment access, and gas controls.

Installing Logs, Embers, and Glass Door

Procedures for correctly installing decorative logs, embers, and the glass door.

Lighting Instructions

Step-by-step procedures for lighting millivolt and electronic ignition fireplaces.

Maintenance

Inspection Procedures

Guidelines for inspecting the venting system, burner flame, and glass gasket.

Cleaning Procedures

Instructions for cleaning the glass door, control compartment, logs, and burner.

Maintenance Schedule

A schedule outlining required maintenance tasks and their frequency.

Troubleshooting

Replacement Parts

Warranty

Superior DRT3040 Specifications

General IconGeneral
BrandSuperior
ModelDRT3040
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals