MAINTENANCE SCHEDULE
See the tables below for detailed information about required maintenance, both regular and annual.
Table 40 - Maintenance Performed Annually—Before the Burning Season
Maintenance Task Performed By Performed By
Inspecting/Cleaning Burner, Logs
and Controls
Qualifi ed Service Technician Inspect valve and ensure it is properly
operating. Check piping for leaks. Vacuum
the control compartment, fi replace logs and
burner area.
Checking Flame Patterns and Flame
Height
Qualifi ed Service Technician Verify the fl ame pattern and height displayed
by the fi replace (Figures 39 and 40). Flames
must not impinge on the logs.
Inspecting/Cleaning Pilot and Burner Qualifi ed Service Technician Remove any surface build-up on pilot and
burner assembly. Wipe the pilot nozzles,
igniter/fl ame rod and hood. Ensure the pilot
fl ame engulfs the fl ame sensor as shown.
Checking Vent System Qualifi ed Service Technician Inspect the vent system at the top and at
the base (within the fi rebox) for signs of
blockage or obstruction. Look for any signs
of dislocation of the vent components.
Fireplace Inspection Qualifi ed Service Technician Perform the appropriate fi replace inspection
procedure detailed in this manual.
Replacing Glowing Embers Homeowner/Qualifi ed Services Technician Remove the old glowing embers and
vacuum the area. Place new glowing embers
(Figure 49).
Replacing Batteries Homeowner/Qualifi ed Services Technician For electronic gas valve models:
Replace the batteries in the battery holder.
Table 41 - Maintenance Performed Periodically—After the Burning Season
Maintenance Task Performed By Performed By
Cleaning Firebox Interior Homeowner Carefully remove logs, volcanic stone and
glowing embers / glass media. Vacuum out
interior of the fi rebox. Clean fi rebox walls and
log grate, if installed. Replace removed items
as detailed in this manual.
Check Flame Patterns and Flame Height Homeowner Verify the fl ame pattern and height displayed
by the fi replace (Figures 39 and 40). Flames
must not impinge on the logs.
Checking Vent System Homeowner Inspect the vent system at the top and at
the base (within the fi rebox) for signs of
blockage or obstruction. Look for any signs
of dislocation of the vent components.
Cleaning Glass Door Homeowner Clean as necessary following the directions
provided in this manual (Page 57). Do not