Chapter 2: Installation
2-19
Power Button
Over heat/Fan Fail L
ED (-)
1
NIC1 LED (-)
Reset Button
2
HDD LED (-)
POWER LED (-)
Reset
PWR
POWER LED (+)
Ground
Ground
X
X
HDD LED (+)
NIC1 LED (+)
Over heat/Fan Fail LED (+)
1516
X
X
Front Control Panel Pin Definitions
Power LED
The Power LED connection is located on
pins 15 and 16 of JF1. Refer to the table
on the right for pin denitions.
Power LED
Pin Definitions (JF1)
Pin# Denition
15 +5V
16 Vcc
A. PWR LED
B. HDD LED
C. NIC1 LED
HDD LED
The HDD LED connection is located on
pins 13 and 14 of JF1. Attach a cable
here to indicate the status of HDD-
related activities, including IDE, SATA
activities. Refer to the table on the right
for pin denitions.
HDD LED
Pin Definitions (JF1)
Pin# Denition
13 Vcc
14 HDD LED
NIC1 (LAN)
The NIC (Network Interface Controller)
LED connection for LAN port 1 is located
on pins 11 and 12 of JF1. Attach an LED
indicator to this header to display net-
work activity. Refer to the table on the
right for pin denitions.
LAN LED
Pin Definitions (JF1)
Pin# Denition
11 Vcc
12 NIC2 LED
A
B
C