Chapter 4: AMI BIOS
4-51
PS Current Threshold1
The PS Current Threshold1 is dened in 1/4A (Amperes) increments
and uses the BIOS mailbox command 0x3. A value of 400 equals 100A.
Valid range is 0-512 which translates to 0-128A. Enter 0 for AUTO.
Default is 80 for 20A.
PS Current Threshold2
The PS Current Threshold2 is dened in 1/4A (Amperes) increments
and uses the BIOS mailbox command 0x3. A value of 400 equals 100A.
Valid range is 0-512 which translates to 0-128A. Enter 0 for AUTO.
Default is 20 for 5A.
PS Current Threshold3
The PS Current Threshold2 is dened in 1/4A (Amperes) increments
and uses the BIOS mailbox command 0x3. A value of 400 equals 100A.
Valid range is 0-512 which translates to 0-128A. Enter 0 for AUTO.
Default is 4 for 5A.
PS3 Enable
Enable or Disables PS3. Uses BIOS VR mailbox command line 0x3.
The options are Disabled and Enabled.
PS4 Enable
Use this feature to enable or disable PS4. This feature uses BIOS VR
mailbox command line 0x3. The options are Disabled and Enabled.
IMON Slope
IMON (Load Current Monitor) Slope is dened in 1/100 increments and
uses the BIOS VR mailbox command 0x4. Valid range is 0-200. For
example, enter 125 for a 1.25 slope. Enter 0 for AUTO.
IMON Offset
IMON Offset is dened in 1/1000 increments and uses the BIOS VR
mailbox command 0x4. For example, enter 25,348 for a 25.348 offset.
Valid range is 0-63999.
IMON Prex
This feature sets the IMON offset value to a positive or negative num-
ber. The options are + and -.