CHECKING THE FLOW METER
In case of water usage, the remaining capacity counter in
the service display will count back per unit, i.e. per litre.
This way the correct functioning of the water meter can be
verified.
MANUAL REGENERATION
Regen in 10 sec
It is possible to manually initiate an immediate
regeneration or a delayed regeneration (at the
preprogrammed time of regeneration).
STEP 1. Press the scroll button; the display will show:
STEP 2. If the control panel is left in this position, the
countdown timer will countdown to 0 sec and start
an immediate regeneration.
To cancel this mode, press the scroll button before the
countdown timer has reached 0 sec; the display will show:
STEP 3. If the control panel is left in this position, a delayed
regeneration will be started at the indicated
preprogrammed time of regeneration.
To cancel this mode, press the scroll button,
the control panel will return to the service mode.
Regen @ 2:00
STEP 1. Press the scroll button and hold it for 2 sec
until the display shows:
Language: English
PROGRAMMING INSTRUCTIONS
(BASIC SETTINGS)
- Before entering the programming mode, make sure that
the appliance is in service mode.
- In case no button is pressed in a period of 5 min, the control
panel will automatically return to the service mode;
any changes made will NOT be saved!
Press the up or down button to set the
language.
STEP 2. Press the scroll button again; the display will
show:
ELECTRONIC CONTROL PANEL
Press the up or down button to set the unit
of measure for water hardness. Make sure it is identical
to the unit of measure of the water hardness test kit
or water analysis report that is used to determine the
hardness of the incoming untreated water!
HardUnit: °f
STEP 3. Press the scroll button again; the display will
show:
Press the up or down button to set the time
of day.
Set time: 8:01
Set Hardn: XX °f
Exit
Press the up or down button to set the hardness
of the incoming untreated water.
Press the up z or down button to save the settings
®
into the NOVRAM and exit the programming mode.
STEP 5. Press the scroll button again, the display will
show:
STEP 4. Press the scroll button again, the display will
show:
NOTE! You should give the value of the compensated
hardness which is the result of: hardness, iron,
manganese and ammonium ion.
Change all the values of the summed parameters
to mg/l. We calculate the compensated hardness
expressed in mg CaCO /l according to the formula:
3
Hardness in mg CaCO /l + 80 x (Iron in mg/l +
3
Manganese in mg/l + Ammonium ion in mg NH /l).
4
Example:
- Hardness = 420 mg CaCO3/l
- Iron = 0.9 mg/l
- Manganese = 0.45 mg/l
- Ammonium ion = 0.7 mg NH4/l
420 mg CaCO /l + 80 x (0.9 mg/l + 0.45 mg/l + 0.7 mg
3
NH /l) = 584 mg CaCO /l
4 3
O
Then, change the units mg/l to f and introduce the
O
value into the appliance (1 mg/l = 0.1 f).
We enter the value of the compensated hardness to the
head of the appliance while programming.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SUPREME MULTI and is the answer not in the manual?

SUPREME MULTI Specifications

General IconGeneral
BrandSUPREME
ModelMULTI
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals