Check for visible damage before setup; do not install or use if damaged.
Use hand truck for transport; avoid hoisting or laying on side.
Keep instructions safe and ensure new users are familiar with content.
Repairs should only be by competent technicians to prevent danger.
Dispose according to WEEE requirements and local laws for recycling.
Optimal performance at 3 bar; check regularly, use reducer if needed.
Avoid high ambient or freezing temps; keep away from water heaters.
Use only 24V AC with supplied transformer in a dry location.
Install a sediment filter ahead of the appliance for high impurity concentration.
Use flexible hoses with large diameter to limit pressure loss.
Recommend 3-valve bypass for isolation during repairs.
Steps to connect the appliance using the factory bypass system.
Steps to install and connect the 3-valve bypass system.
Use stand pipe with air trap; minimum 2x diameter air gap to prevent backflow.
Use separate hoses; minimize pressure loss, avoid kinks and elevations.
Ensure sewerage system can handle rinse water flow rate.
Plug transformer output to appliance cord and transformer to outlet.
Ensure bypass is in bypass position and controller in service mode.
Open mains supply, run faucet to purge air and flush debris.
Gently pressurize by opening valves according to bypass type.
Fill brine tank to 3/4 with salt, then to 1/2 with water; wait for brine solution.
Program the electronic controller settings.
Manually initiate regeneration via the scroll button.
Shows 'Service Required' for timer issues.
Shows 'Maintenance Now' when interval is reached.
Displays time of day and volume (e.g., 8:01 1000L).
Shows cycle, remaining regeneration/cycle time.
Displays installed software version for 5 seconds.
Program stored in NOVRAM; SuperCap maintains time for hours.
Returns to service mode; resumes regeneration upon power restoration.
Remaining capacity counter counts back per litre for verification.
Press scroll to show 'Regen in 10 sec' for immediate regeneration.
Press scroll before countdown ends to cancel immediate regeneration.
Leave display showing 'Regen @ 2:00' to start at preprogrammed time.
Ensure appliance is in service mode before entering programming.
Use up/down buttons to set the time of day.
Set water hardness unit (e.g., °f) to match test kit.
Set compensated hardness value based on water analysis.
Use up/down buttons to select display language.
Press scroll to exit; changes auto-saved if within 5 min timeout.
Verify settings of the electronic control panel.
Measure contamination before and behind the appliance.
Check drain line for water flow (unless regenerating).
Check cabinet overflow drain line for water flow.
Inspect appliance and surrounding area for water leaks.
Inlet/outlet valves to appliance are CLOSED.
Inlet/outlet valves to appliance are OPEN.
Inlet valve OPEN, outlet valve CLOSED.
Bypass valve CLOSED; inlet/outlet valves OPEN.
Keep salt level between 1/3 and 2/3 to ensure proper saturation.
Methods to break salt bridges: pounding, pushing, or warm water.
User should periodically check and refill salt if necessary.
Wipe with damp cloth or mild soap; avoid abrasive cleaners.
Risk of bacteria in stagnant water; 'days override' feature rinses periodically.
Manually initiate a complete regeneration after prolonged power loss.