OPERATING INSTRUCTIONS
THIS UNIT IS INTENDED TO BE USED WITH COLD WATER ONLY! DO NOT USE HOT
WATER IN THIS PRESSURE CLEANER!
Starting Up
After connecting the pressure cleaner to your cold water supply, proceed as follows:
- Make sure that the on/off switch is in the off position.
- Connect the garden hose to the inlet fitting.
- Attach the hose to the gun as per assembly instruction step #1.
- Insert the adjustable spray nozzle into the gun as per assembly step #3.
- Connect the high pressure hose to the high pressure outlet fitting as per assembly step
#4.
- Connect the garden hose to the high pressure washer inlet fitting as per assembly step#5.
- Open the water supply valve completely.
- Before turning the unit on, press the gun trigger to bleed all the remaining air out of the
pump and hose.
- Start the pressure cleaner by turning the on/off switch to the on position and squeeze the
trigger. REMINDER: Motor does not run continuously, only when the trigger is squeezed.
WARNING RISK OF INJECTION! Unit will start spraying when trigger is squeezed.
When turning the unit off after use, high pressure still exists inside the hose and
unit. Point the gun in a safe direction and discharge the excess pressure. NEVER
direct the high pressure water stream at people or animals.
Automatic On/Off
The pressure cleaner is equipped with an automatic on/off switch. The pressure cleaner will only
run when the power switch is in the ON position and the trigger on the gun is squeezed. When
you release the trigger to stop spraying water through the gun, the motor on the pressure cleaner
will automatically shut off. Simply squeeze the trigger again to resume using the cleaner. To stop