CHARGING
SYSTEM
INSPECTION
CHARGING
OUTPUT
CHECK
e@
Remove
the
left
and
right
frame
covers
and
seat.
(Refer
to
page
3-2)
Start
the
engine
and
keep
it
running
at
5000
r/min
with
lighting
switch
turned
ON
and
dimmer
switch
turned
HI
position.
e
Using
the
pocket
tester,
measure
the
DC
voltage
between
the
battery
terminals,
®
and
©.
If
the
tester
reads
under
13.5V
or
over
15.5V,
check
the
AC
generator
no-load
performance
or
replace
the
regulator/rectifier.
NOTE:
When
making
this
test,
be
sure
that
the
battery
is
fully-charged
condition.
STD
charging
13.5
15.5V
(DC)
output
at
5
000
r/min
09900-25002
Pocket
tester
AC
GENERATOR
NO-LOAD
PERFORMANCE
©
Remove
the
left
frame
cover.
©
Disconnect
the
AC
generator
lead
wire
connec-
tor
from
the
regulator/rectifier.
©
Start
the
engine
and
keep
it
running
at
5000
r/min.
©
Using
the
pocket
tester,
measure
the
AC
voltage
between
the
three
yellow
lead
wires.
If
the
tester
reads
under
80V,
the
AC
generator
(stator
or
rotor)
is
faulty.
STD
No-load
per-
formance
(when
engine
is
cold)
hs
09900-25002
Pocket
tester
More
than
80V
(AC)
at
5000
r/min