16. ELECTRICAL EQUIPMENT SYM
16-6
Battery
Removal
Remove the 4 screws on the battery cover.
(Screws x 4).
CAUTION
Remove the battery cover.
Disconnect the negative (-) cable from the
battery first, then the positive (+) cable.
Remove the battery.
Install the battery in reverse order of
removal.
CAUTION
Electrolyte (diluted sulfuric acid) is very
toxic. Once it spreading on clothes, skin,
or eyes, it will cause burned or blind. In
case of being spread, flush with great
quantity of water immediately, and then
send to hospital.
When clothes is spread by electrolyte, it
will contact with skin. So, it must flush
with great quantity water to take off the
clothes.
To prevent form circuit short, connect
positive(+) terminal at first, and next
negative (-) terminal.
positive (+) negative (-)
C.D.I.
fuse
Battery
cover
4 screws