ZV-3247 REV B
Temptrol
®
Pressure Balancing Valve
Installation Instructions
262BODY
(4 PORT)
262XBODY
(4 PORT, SERVICE STOPS)
261XBODY
(3 PORT, SERVICE STOPS)
IMPORTANT / FOR INSTALLER
WARNING:
As the installer of this valve, you must first carefully read and understand the material covered in this manual before
installing and adjusting this valve per instructions. Failure to do so may compromise the installation, operation and/or
serviceability of this valve.
Do not install positive shut-o devices on the outlet of this valve, or devices that do not allow the valve to flow at
least 1.5 GPM at 45 psi inlet pressure. Exception: If a self-closing or slow-closing valve is installed on the outlet, the
supplies of the valve must be equipped with checks to eliminate hot to cold bypass in the event the valve’s handle is
not turned o after use.
When installing this valve, failure to adjust limit stop screw properly may result in serious scalding.
COMPLIANCE
-ASME A112.18.1/CSA B125.1
-ASSE 1016
-Buy American Act Compliant
LIFETIME LIMITED WARRANTY
All warranty claims MUST be pre-approved by Symmons.
All parts and finishes of the Symmons products are
warranted to the original consumer purchaser to be free
from manufacturing defects in material and workmanship
for 5 years Non-Residential or Commercial Applications.
Symmons warrants to the original consumer purchaser/
end-user that any Symmons product will be free of
defects in material and workmanship during normal
domestic use for the life of your home.
Symmons recommends using a professional plumber
for all installation and repair. During the warranty
period, Symmons at its sole option, will provide
replacement part(s) or product (or, if no longer available,
a comparable product) to replace those which have
proven defective in materials or workmanship under
normal installation, use and service, FREE OF CHARGE
for the time period of 5 years from the date of purchase.
(BATTERIES NOT INCLUDED)
This warranty is extensive in that it covers replacement of
all defective parts and even finish, but these are the only
two things that are covered. Damage due to installation
error, product abuse, product misuse, or use of cleaners
containing abrasives, alcohols, or other organic solvents,
whether performed by a contractor, Service Company
or yourself are excluded from this warranty. Symmons
will not be responsible for labor charges and/or damage
incurred in installation or repair or replacement, nor for
any indirect, incidental or consequential damages, losses,
injury or costs of any nature relating to the bathing
products. Except provided by law, this warranty is in
lieu of and excluded all other warranties, conditions and
guarantees, whether expressed or otherwise, including
without restriction those of merchantability or of fitness
for use.
Some states do not allow the exclusion or limitation
of incidental or consequential damages, so the above
limitation of exclusion may not apply to you. This
warranty gives you specific legal rights, and you also may
have other rights which vary from state to state. This
warranty is not transferable. This warranty does not cover
damage or defects relating to misuse, abuse, negligence,
normal wear and tear, accident, acts of God, repairs or
alterations not authorized in writing by Symmons, or
improper installation, storage or handling.
The above mentioned warranty information includes each
product that falls under the following: Symmons Bathing
Products Warranty- Non-Residential or Commercial
Applications; Symmons Non-Electronic Lifetime
Faucet and Finish Limited Warranty Non-Residential or
Commercial Applications; Symmons Electronic Faucet
Limited Warranty - Non-Residential, Commercial and
Residential Applications; Symmons Bathing Products
Warranty- Residential Application Symmons Non-
Electronic Lifetime Faucet and Finish Limited Warranty
Residential Application
If you have any questions regarding technical support,
installation or concerns regarding our warranty plan,
please email us at GetHelp@symmons.com or call us at:
1-800-796-6667.
RTS-076
(BRACKET)

Questions and Answers

  • N
    Nicole GeorgeJul 27, 2025
    What to do if Symmons Control Unit temperature varies without moving handle?
    • T
      thomasjanetJul 27, 2025
      If the temperature varies without you adjusting the handle, it's likely that the pressure-balancing piston inside the spindle assembly is blocked by foreign particles. To resolve this, open the valve halfway, take off the handle, and gently tap the spindle using a plastic hammer. Inspect the water pressure balancing piston within the control spindle, referring to the service instructions for guidance. Consider replacing the TA-10 flow control spindle.
  • D
    Danielle CampbellJul 31, 2025
    What to do if Symmons Temptrol 262BODY Control Unit delivers sufficient quantity of cold, but little hot, or the reverse?
    • G
      glenkrauseAug 1, 2025
      If your Symmons Control Unit delivers plenty of cold water but very little hot water (or vice versa), it's likely that the pressure-balancing piston in the spindle assembly is being restricted by foreign matter. To fix this, open the valve halfway, remove the handle, and tap the spindle with a plastic hammer. Also, check the water pressure balancing piston in the control spindle, and refer to the service instructions. Replacing the TA-10 flow control spindle may also resolve the issue.
  • S
    Sharon NewtonAug 5, 2025
    What to do if the Symmons Temptrol 262BODY Control Unit temperature control handle is turned from cold to hot and volume from spout or head is not constant?
    • N
      Nicole DixonAug 5, 2025
      If you're experiencing inconsistent water volume from the spout or showerhead while adjusting the temperature on your Symmons Control Unit, it's probably due to the pressure-balancing piston in the spindle assembly being blocked by foreign particles. Try opening the valve halfway, removing the handle, and gently tapping the spindle with a plastic hammer. Inspect the water pressure balancing piston in the control spindle, consulting the service instructions. Replacing the TA-10 flow control spindle might be necessary.
  • B
    Brian FitzgeraldAug 8, 2025
    Why does Symmons Temptrol 262BODY deliver hot water when initially opened, then turns colder?
    • E
      Evan JohnsonAug 8, 2025
      If your Symmons Control Unit initially dispenses hot water that gradually turns colder as you rotate the handle towards the hot position, the valve is likely piped incorrectly. The hot supply is connected to the valve’s cold inlet, and the cold supply to the hot inlet. If the piping is accessible, correct the connections to the valve. If not, order a T-108 reverse seat and tool kit. Older installations might also need a replacement of the TA-4 hot/cold seat repair kit.
  • L
    lisamillerAug 13, 2025
    What to do if Symmons Temptrol 262BODY Control Unit valve leaks when shut off?
    • A
      Ashlee MendezAug 13, 2025
      If your Symmons Control Unit valve is leaking after being shut off, the hot and cold washers are likely worn, or there's foreign matter (like dirt or chips) trapped between the washers and seat surfaces. Replace the washers using a TA-9 washer repair kit. Also, replace the hot and cold seats using a TA-4 hot/cold seat repair kit.
  • A
    Andrew BakerAug 17, 2025
    Why does Symmons Temptrol 262BODY Control Unit delivery temperature reduce gradually during use?
    • M
      Matthew MccormickAug 17, 2025
      If the water temperature from your Symmons Control Unit gradually decreases during use, requiring you to turn the handle to hotter positions to maintain a constant temperature, it's likely due to an overdraw on the hot water supply (i.e., running out of hot water). To fix this, reduce the maximum flow by adjusting the volume control on the valve or showerhead. This will allow for a longer period of use before the hot water supply is depleted.
  • K
    Kim FernandezAug 21, 2025
    How to fix Symmons Temptrol 262BODY that will not pass water?
    • M
      Monique DominguezAug 22, 2025
      If your Symmons Control Unit isn't dispensing any water, it's likely that either the hot or cold water supplies (or both) are not turned on. Ensure that both supplies are fully turned on, as the valve requires pressure from both hot and cold water to operate.

Summary

Mounting Bracket Installation

Install Bracket

Instructions for locating and attaching the mounting bracket to wall studs using wood screws.

Valve Body Installation

Set Temperature Limit Stop Screw

Instructions for adjusting the temperature limit stop screw to prevent scalding.

Back to Back Installation

Service Instructions

Checking Water Pressure Balancing Piston

Guidance on checking the function of the water pressure balancing piston in the spindle.

Troubleshooting Chart

Valve Will Not Pass Water

Addresses issues where the valve fails to pass water, typically due to supply problems.

Valve Leaks When Shut Off

Diagnoses leaks after shut-off, often caused by worn washers or foreign matter.

Temperature Control Handle Issues

Covers inconsistent volume or temperature variations with handle movement.

Incorrect Water Delivery

Addresses problems like insufficient hot/cold water or temperature fluctuations.

Piping Errors

Identifies and resolves issues caused by incorrect hot and cold water supply connections.