Home
SystemAir
Fan
SAVE VSR 500
SystemAir SAVE VSR 500 Installation And Service
4
of 1
of 1 rating
48 pages
Give review
Manual
Specs
To Next Page
To Next Page
Loading...
Document
in
original
language
|
211458
·
A002
SAVE
VSR
300/500
Installation
and
Servic
e
GB
2
Table of Contents
Default Chapter
3
Table of Contents
3
1 Declaration of Conformity
5
2 Disposal and Recycling
6
3 Warnings
6
4 About this Document
6
5 Product Information
6
General
6
Installation Recommendation Regarding Condensation
7
Condensation Inside of the Unit
7
Condensation Outside of the Unit
7
Transport and Storage
7
Technical Data
8
Dimensions and Weight of VSR 300
8
Dimensions and Weight of VSR 500
9
Duct Connections
9
Power Consumption and Fuse Size
9
6 Installation
10
Unpacking
10
Where/How to Install
10
Installation Procedure
10
Condensation Drainage
11
7 Electrical Connections
11
Main Board Layout
12
External Connections (Connection Board)
13
8 Savecair Control
14
General
14
Startup Wizard
14
Common Symbols
14
Menu Overview
15
Home Screen
16
User Modes
16
Temperature Settings
18
Airflow Settings
18
Indoor Air Quality
19
Status Line
19
Description of User Function Icons
19
Main Menu
20
Unit Information
20
Alarms
21
Week Schedule
24
Filter
25
System Preferences
26
Service
26
Help
32
9 Service
33
Warnings
33
Internal Components
34
Component Descriptions
34
Replacing Rotor Drive Belt
36
Troubleshooting
36
10 Accessories
38
Internet Access Module (IAM)
38
Mobile Application and Login
38
10.2 Indoor Air Quality Sensors
38
10.3 Temperature Control
40
Electrical Duct Pre-Heater
40
Duct Water Heater
41
Duct Water Cooler
42
Change-Over Coil (DX)
43
10.4 Airflow Control
45
VAV/CAV Conversion Kit
45
10.5 Installation/Maintenance
46
Outdoor/Exhaust Air Dampers
46
10.6 Filters
47
10.7 Passive House Function
47
Other manuals for SystemAir SAVE VSR 500
User Manual
25 pages
Service & Accessories Installation Manual
48 pages
Installation Instructions
18 pages
How-To
8 pages
Installation Guide
6 pages
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the SystemAir SAVE VSR 500 and is the answer not in the manual?
Ask a question
SystemAir SAVE VSR 500 Specifications
General
Supply voltage
230 V
Phase
1~
Frequency
50 Hz
Heat exchanger type
Counterflow
Filter class extract air
ePM10 50% (M5)
Operating temperature
-20°C to +40°C
Related product manuals
SystemAir SAVE VSR 300
25 pages
SystemAir SAVE VTC 300
70 pages
SystemAir SAVE VTR 200/B
19 pages
SystemAir SAVE VTR 300/B
25 pages
SystemAir SAVE VTR 250/B
94 pages
SystemAir SAVE Series
8 pages
SystemAir SAVE CONNECT 2.0
24 pages
SystemAir VSR 300
52 pages
SystemAir K 315 L sileo
36 pages
SystemAir K 160 XL sileo
36 pages
SystemAir SYSCOIL COMFORT 10
40 pages
KA HSI-2-2-S-R-50F-TB2-L2
64 pages