EasyManua.ls Logo

T.I.P. DRAIN 6000/36 - User Manual

T.I.P. DRAIN 6000/36
124 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Gebrauchsanweisung
HOCHDRUCK-TAUCHPUMPE
01
Operating Instructions
HIGH-PRESSURE IMMERSION PUMP
08
Mode d’emploi
POMPE SUBMERSIBLE A HAUTE
PRESSION
14
Istruzioni per l’uso
POMPA SOMMERSA AD ALTA
PRESSIONE
20
Instrucciones para el manejo
BOMBA SUMERGIDA DE ALTA PRESIÓN
26
Handleiding
HOGEDRUK-DOMPELPOMP
32
Οδηγίες Χρήσης
ΒΥΘΙΜΕΝΗ ΑΝΤΛΙΑ ΥΨΗΛΗΣ ΠΙΕΣΗΣ
38
Használati utasítás
MAGASNYOMÁSÚ BÚVÁRSZIVATTYÚ
45
Instrukcja użytkowania
POMPA ZANURZENIOWA
WYSOKOCIŚNIENIOWA
51
Uživatelský návod
VYSOKOTLAKÉ PONORNÉ ČERPADLO
57
Kullanım Talimatı
YÜKSEK BASINÇLI DALGIÇ POMPA
63
Упътване за употреба
ПОТОПЯЕМА ПОМПА ЗА ВИСОКО
НАЛЯГАНЕ
69
Instructiuni de utilizare
POMPĂ SUGMERSIBILĂ DE ÎNALTĂ
PRESIUNE
76
Upute za uporabu
VISOKOTLAČNA PODVODNA CRPKA
82
Návod na použitie
VYSOKOTLAKOVÉ PONORNÉ
ČERPADLO
88
Navodila za uporabo
VISOKOTLAČNA POTOPNA ČRPALKA
94
Инструкция по эксплуатации
Погружной насос высокого давления
100
ІНСТРУКЦІЯ З ЕКСПЛУАТАЦІЇ
ЗАГЛИБНИЙ НАСОС ВИСОКОГО ТИСКУ
107
DRAIN 6000/36

Table of Contents

Questions and Answers

  • G
    grimesallenJul 29, 2025
    Why T.I.P. DRAIN 6000/36 is not discharging any liquid and the motor isn't running?
    • R
      Rebecca HinesJul 29, 2025
      If your T.I.P. Water Pump isn't discharging liquid and the motor isn't running, here are a few things to check: * **No current:** Verify voltage presence with a GS-compliant device and check the plug's position. * **Thermal motor protection:** Let the system cool down and eliminate the cause. * **Blocked pump wheel:** Clear any blockage of the pump wheel.
  • T
    Tyler PetersenAug 4, 2025
    What to do if my T.I.P. DRAIN 6000/36 Water Pump stops quickly due to thermal motor protection?
    • T
      Timothy HillAug 5, 2025
      If your T.I.P. Water Pump stops shortly after starting due to thermal motor protection, it could be due to several reasons: * **Incorrect electrical supply:** Ensure the electrical supply matches the type plate information using a GS-compliant device to check the connection cord voltage. * **Blocked pump/intake:** Remove any blockages from the pump or intake openings. * **Viscous liquid:** The pump might not be suitable for the liquid, consider thinning it if possible. * **High liquid temperature:** Ensure the liquid temperature doesn't exceed the maximum admissible value. * **Dry running:** Eliminate the causes of dry running.
  • B
    Brandon MitchellAug 10, 2025
    How to fix a T.I.P. Water Pump when the motor runs but no liquid is discharged?
    • M
      morajamesAug 10, 2025
      If the motor of your T.I.P. Water Pump is running but no liquid is being discharged, consider these potential issues: * **Clogged intake openings:** Remove any obstructions from the intake openings. * **Clogged pressure line:** Clear any blockages in the pressure line. * **Air in pump body:** Start the pump several times to expel trapped air. * **Low suction level/Floating switch issues:** Ensure the minimum suction level is met, adjust the floating switch if necessary, and ensure it moves freely. * **Blocked/defective check valve:** Clear any blockages in the check valve or replace it if damaged.
  • G
    gturnerAug 17, 2025
    Why is my T.I.P. DRAIN 6000/36 operating intermittently?
    • E
      Emily LarsonAug 17, 2025
      If your T.I.P. Water Pump is operating intermittently, there could be a few reasons: * **Pump wheel obstructed:** Remove any solid matter that might be obstructing the pump wheel. * **Mains voltage out of tolerance:** Ensure that the mains voltage matches what's indicated on the type plate.
  • J
    Jennifer EvansAug 23, 2025
    What causes a T.I.P. DRAIN 6000/36 to not cut in or out?
    • R
      Robert Cherry MDAug 23, 2025
      If your T.I.P. Water Pump isn't cutting in or out, check the following: * **Floating switch movement:** Make sure the floating switch can move freely. * **Floating switch setting:** Correct the floating switch settings if they are incorrect.

Summary

General Safety Information

Range of Use

Technical Data

Scope of Delivery

Installation

General Installation Information

Installation requires the device to remain disconnected from mains power.

Pressure Line Installation

Use a large diameter pressure line, ideally matching the pump outlet, to avoid friction losses.

Stationary Installation

Rigid pipes are recommended for stationary installations, with a check valve for preventing backflow.

Floating Switch Adjustment

Adjust the cut-in and cut-out levels by modifying the floating switch cable length.

Pump Positioning

Position the pump ensuring max. submersion depth is not exceeded and it sits on solid ground.

Electrical Connection

Putting Into Operation

Automation with Special Accessories

Maintenance and Troubleshooting

Warranty Information

Ordering Spare Parts

Service and Support

T.I.P. DRAIN 6000/36 Specifications

General IconGeneral
BrandT.I.P.
ModelDRAIN 6000/36
CategoryWater Pump
LanguageEnglish

Related product manuals