14 Installation TB7100 Installation Guide
© Tait Electronics Limited March 2006
1.8.3 Mounting the Base Station
1. Fit the base station into the cabinet or rack and secure it firmly with 
an M6 (or 0.25in if you are using imperial fittings) screw, flat and 
spring washer in each of the four main mounting holes 
b, as shown 
in Figure 1.3 on page 14.
2. The base station can be wall-mounted by rotating the front mounting 
brackets and fitting the optional rear brackets (TBBA03-01). When 
the base station is wall-mounted ensure the airflow is from bottom to 
top (front panel mounted down) or side to side.
3. For transport or in installations subject to vibration, the base station 
should be supported at the rear using a transit bracket 
(Tait recommends to use the TB7100 transit bracket, Tait part 
number TBBA03-04).
Figure 1.3 Base station mounting points (configuration with AC power supply unit shown)
b
main mounting holes
e
DC power connector
c
base station
f
AC power connector
d
ground point
G
rack frame
G
E
c
b
f
D