11. REMOTE CONTROLLER (OPTIONAL ITEM)
The water heater can be installed with up to three remote controllers. The remote controller


The output water temperature can be adjusted only by a remote controller which has the



heater. (Default set temperature is 40 °C.)

-


 must be installed in dry, shaded and clean locations (such as kitch-
en) due to NO water resistant. Be careful of installation location.
The controller can adjust the output water temperature within the range from 37 °C to 50 °C
when it is connected to GS-20W/26W-AU5. (See the chart below.)
The controller can adjust the output water temperature with in the range from 37 °C to 60 °C
when it is connected to GS-20W/26W-AU6. (See the chart below.) When “BURNER ON lamp
is on, the set temperature can not be adjusted to 55 and 60 °C. If you want to set it to 55
and 60 °C, you should close the hot water tap.

 and controllers are water resistant, however should not be posi-

of the wall and the controller.
 is installed such as the main bathroom, and  is installed such as the
ensuite bath room.
The controllers can adjust the output water temperature within the range from 37 °C to 50 °C.
(See the chart below.)
When BURNER ON lamp is on, the set temperature can not be adjusted to 42 °C or over. If you
want to adjust the set temperature to 42 °C or over , you should close the hot water tap.
Main

Shower

Ensuite


*Factory setting (Default): 40 °C
**Setting of the output temperature of 55 °C and 60 °C are only available when it is connected to GS-20W/26W-AU6.

37 38 39 40* 41 42 43 44 45 46 47 50 55** 60**

37 38 39 40* 41 42 43 44 45 46 47 50

(Unit:°C)