TROUBLESHOOTING
TROUBLESHOOTING
TROUBLESHOOTING
12 • On-Demand Water Heater Service Handbook for 240, 340 & 540 Condensing Models
ERROR CODE
GREEN LED ON
COMPUTER BOARD
SYMPTOM OR ISSUE 
321 Two Flashes Inlet thermistor failure 
331 Two Flashes
Outlet thermistor failure
(540 model only)

341 Two Flashes
Exhaust thermistor
failure
(indoor models only)


Two Flashes
Air-fuel ratio rod failure .
441
Two Flashes
Flow Sensor Failure
(Easy-Link or Multi-Link
System)


510
Six Flashes
Abnormal main gas
solenoid valve (MV)

.
551
Six Flashes
Abnormal gas solenoid
valve (SV1, SV2, and/
or SV3)

.
611 Four Flashes Fan motor fault .
651 Four Flashes
Flow adjustment valve
fault (Easy-Link or Multi-
Link System)

.
661 Four Flashes
Bypass valve fault 
.
701 One Flash
Computer board fault 
.
711 One Flash
Gas solenoid valve drive
circuit failure

.
721 Six Flashes False flame detection .
741 N/A
Miscommunication
between water heater
and remote controller
.
751 N/A
Miscommunication
between water heater
and temperature
controller (Indoor
model only)
.
761 N/A
Miscommunication
between units in an
Easy-Link or Multi-Link
system. (540/T-H3 Only)

