necessary safety and auxiliary equipment to conform to code requirements and design
practice.
For more details, contact Technical Department at (888) 882-5244
Dual-purpose hot water heating (Domestic and Heating):
Priority Control Devices: It has a capability to make priority system that can be used as a
controller flow sensor, Aquastat, or electronic controller to controlling radiant, Hydro or
baseboard heating equipments.
Warning: Follow all local codes, or in the absence of local codes, follow the most recent
edition of the National Standard Code, ANSI Z21. 10.3.
Warning: This illustration is for concept only. There are a wide variety of variations to the
application of controls and equipment presented applications. Designers must add all
necessary safety and auxiliary equipment to conform to code requirements and design
practice.
For more details, contact Technical Department at (888) 882-524
Pressure Relief Valve
Air Vent
Pum
p
Ex
p
ansion Tank
Radiant, Hydro or Baseboard
Heating Equipment.
Check Valve
Domestic
potable water
Cold water su
pp
l
y
Priorit
y
Control Devices