Squeegee assembly
Filling the fresh water tank
Dosing
Dosing examples:
Pre-cleaning
• The machine must be switched off.
• Put the squeegee under the squeegee suspension.
• Position the squeegee under the
shackles of the squeegee holder (1)
so that they fit into the recesses of
the squeegee (2).
• Press down the squeegee holder un-
til the squeegee engages.
• Firmly attach both suction hoses to the sockets of the
squeegee.
Attention:
Max. permissible water temperature
60 °C/140 °F.
Diversey recommends using cold water
since hot water will adjust to the floor tem-
perature as soon as it is in contact with the
floor. Thus there are no advantages to us-
ing hot water.
• The machine must be switched off.
• Open the tank lid.
• Put the fresh water tank (Flextank) onto the provided fix-
ture.
• Take the dosing cup from the fresh water tank (Flextank).
• Fill water into the fresh water tank
(Flextank).
The upper red marking indicates the
max. permissible filling level.
• Tip the tank cover back into its original position and press
it down until it locks.
Attention:
Wear gloves, goggles and appropriate
(protective) working clothes when han-
dling chemical products!
Notice:
Use chemical products recommended by
Diversey only and always observe the
product information.
Caution:
Using unsuitable products (e.g. products
containing chlorine, acids or solvents) may
cause harm to health and severe damage
to the machine.
Information on the packing of
the product
Tank capaci-
ty
Product vol-
ume per tank
filling
0.5% 50ml for 10l
of water
113l 0.5l
1% 100 ml for 10l
of water
113l 1.1l
2% 200 ml for 10l
of water
113l 2.2l
3% 300 ml for 10l
of water
113l 3.3l
• Fill the dosing cup with a suitable product and pour the con-
tent into the fresh water tank. Repeat the procedure until
the required dosing is reached.
• When dosing is finished, the dosing cup will remain in the
tank.
Notice:
TASKI offers an automatic dosage feature
as an option. It is possible to mount it addi-
tionally. Please contact your customer ser-
vice.
Attention:
Remove any objects (wooden, metal parts
etc.) from the cleaning surface.
The objects could be catapulted by the ro
-
tating tool, and thereby cause injuries to
people and damage to the environment.