Page #7 background image
16
D760M
8 - 9 - 10 MOTOR M2
MOTOR M2 power output, 230 Vac, max. 300 W.
8=CLOSE, 9=COMMON., 10=OPEN.
Notice: 
11 - 12 OPEN/CLOSE
OPEN/CLOSE button input (contact normally open); for operating
information see dip-switches 2 and 3 functions. (COMMON=11);


11 - 13 PEDESTRIAN
N.O. PEDESTRIAN button contact input – commands total opening
and closing of motor 1 – governed by dip-switches 2 and 3.
(COMMON=11);


11 - 14 STOP
STOP button input (normally closed contact); this stops the automatic
system. At the next command, the opposite operation to the previous
one is performed (COMMON=9). Bridge the connectors if not used;
15 - 18
SENSITIVE
EDGE
SENSITIVE EDGE input (potential free contact N.C., dip 10 OFF) or

It works during both the opening and closing phases, causing the
temporary stop of the automation and its partial movement reversal
for 20cm, therefore freeing any obstacle (18=COMMON) Note: short-
circuit if not used.
16 - 18
INTERNAL
PHOTOCELLS
PHOTOCELL OR SAFETY DEVICE input INSIDE the automation
(Normally Closed contact); COMMON=18.
When these devices trigger during the opening phase, they tem-
porarily stop the automation until the obstacle has been removed;
during the closing phase they stop the automation and then totally
open it again. Bridge the connectors if not used.
17 - 18
EXTERNAL
PHOTOCELLS
PHOTOCELL OR SAFETY DEVICE input OUTSIDE the automation
(Normally Closed contact); COMMON=18.
Then these devices trigger during the closing phase, they stop the auto-
mation and then totally open it again. Bridge the connectors if not used.
        
  
-
         

19 - 20 ELECTRIC LOCK ELECTRIC LOCK power output 12 Vac max. 15 W;
21 - 22 2
nd
RADIO CH
2nd RADIO CHANNEL output; the output mode can be selected
through Dip Switches 7 - 8;
         

23 - 24
GATE OPEN
WARNING LIGHT
GATE OPEN WARNING LIGHT output; 24 V ac, max 3W; the light

entire opening and closing manoeuvre and remains on if the gate is
open and off when the gate has closed;
25 - 27 PHOTOCELL TX
24 Vac external transmitting photocell power supply output for safe-
ty device control (connect the external TX photocell only) max. of 2
photocell transmitters;
26 - 27 AUX
24Vac output, 10W for the power supply of photocells, external re-
ceivers, etc.
28 - 29 AERIAL AERIAL input (EARTH=28, SIGNAL=29);