EasyManua.ls Logo

Taylor 336 - Operating Procedures: Section 6 Continued; Cleaning Procedure (Steps 1-7); Disassembly Procedure

Taylor 336
53 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
Models 336, 338 & 339 Operating Procedures
Cleaning
Step 1
Prepare a pail of approved 100 PPM cleaning solution
(examples: 2--1/2 gal. [9.5 liters] of Kay--5R or 2 gal.
[7.6 liters] of Stera--SheenR). USE WARM WATER
AND FOLLOW THE MANUFACTURER’S SPECI FIC-
ATIONS.
Step 2
Push down the prime plug. Pour the cleaning solution
into the mix hopper.
Step 3
While the solution is flowing into the freezing cylinder,
brush clean the mix hopper, mix level sensing probe,
and the mix inlet hole.
Step 4
Press the “W ASH” button. This will cause the cleaning
solution in the freezing cylinder to agitate.
Step 5
Place an empty pail beneath the door spout and raise
the prime plug.
Step 6
When a steady stream of cleaning solution is flowing
from the prime plug opening in the bottom of the
freezer door, lower the draw handle. Draw off all of the
solution.
Step 7
Once the cleaner stops flowing from the door spout,
raise the draw handle and press the “W ASH” button,
cancelling the “WASH” mode.
Repeat Steps 1 through 7 for the other side of the
freezer.
Disassembly
Step 1
BE SURE THE POWER SWITCH IS IN THE
“OFF POSITION. MAKE SURE NO LIGHTS ARE
LIT ON THE CONTROL PANEL.
Step 2
Remove the handscrews, freezer door, beaters,
scraper blades, and drive shafts from the freezing
cylinders. Take these parts to the sink for cleaning.
Step 3
Remove the front drip tray and the splash shield.
Brush Cleaning
Step 1
Prepare a sink with an approved cleaning solution
(examples: Kay--5R or Stera--SheenR). USE WARM
W ATER AND FOLLOW THE MANUFACTURER’S
SPECIFICATIONS. If another approved cleaner is
used, dilute it according to the label instructions.
(IMPORTANT: Follow the label directions. Too
STRONG of a solution can cause parts damage, while
too MILD of a solution will not provide adequate
cleaning.) Make sure all brushes provided with the
freezer are available for brush cleaning.
Step 2
Remove the seals from the drive shafts.
Step 3
From the freezer door remove:
S gaskets
S front bearings
S pivot pins
S adjustable draw handles
S design caps
S draw valves
S prime plugs
Remove all o--rings.
Note: To remove o--rings, use a single service towel
to grasp the o--ring. Apply pressure in an upward
direction until the o--ring pops out of its groove. With
the other hand, push the top of the o--ring forward and
it will roll out of the groove and can be easily removed.
If there is more than one o--ring to be removed, always
remove the rear o--ring first. This will allow the o--ring
to slide over the forward rings without falling into the
open grooves.

Other manuals for Taylor 336