28
General Service
Models 358 & 359
j 8. On air-cooled units, check the condenser filter
for an accumulation of dirt and lint. Dirty
condensers will reduce the efficiency and
capacity of the machine. The condensers
should be cleaned monthly. Remove the hood
to gain access to the condensers. Use a soft
brush to clean between the fins of the
condenser. Never use screwdrivers or other
metal probes to clean between the fins.
CAUTION: Always disconnect
electrical power prior to cleaning the
condenser. Failure to follow this
instruction may result in electrocution.
j 9. On water cooled units, check the water lines for
kinks or leaks. Kinks can occur when the
machine is moved back and forth for cleaning or
maintenance purposes. Deteriorated or
cracked water lines should be replaced only by
an authorized Taylor service technician.
j 10. Inspect the drive shaft for wear and damage on
a monthly basis.