15
Models 441 & 444 Operating Procedures
080924
Insert the baffle rod through the beater in the freezing
cylinder. With the door seated on the freezer studs,
install the handscrews. T ighten equally in a crisscross
pattern to insure that the door is snug.
Figure 13
Rotate the draw valve bracket to the left. Center it into
position by raising the draw arm and placing it into the
slotted groove of the draw valve bracket.
Figure 14
Step 5
Lay the mix feed tube and the hopper gasket in the
bottom of the mix hopper .
Note: Hopper gaskets are not used on the Model 444.
Repeat Steps 1 through 5 for the other side of the
freezer on the Model 444.
Step 6
Install the front drip tray and splash shield under the
door spout(s).
Figure 15
Step 7
Slide the rear drip pan into the hole(s) in the side panel.
Sanitizing
Step 1
Prepare a pail of approved 100 PPM sanitizing solution
(examples: 2- 1/2 gal. [9.5 liters] of Kay- 5R or 2 gal.
[7.6 liters] of Stera- SheenR). USE WARM WATER
AND FOLLOW THE MANUFACTURER’S SPECI FIC-
ATIONS.
Step 2
Pour the sanitizing solution into the hopper and allow
it to flow into the freezing cylinder.
Figure 16