OPERATING PROCEDURES
6-7
Models 750, 751, 754, 774, 791, and 794
Operating Procedures
6
Figure 6-23
4. Place the power switch in the ON position.
Figure 6-24
5. Press the WASH button. This will cause the
sanitizing solution in the freezing cylinder to agitate.
Allow it to agitate for 5 minutes.
Figure 6-25
6. Place an empty pail beneath the door spout and raise
the prime plug.
Figure 6-26
7. When a steady stream of sanitizing solution is
flowing from the prime plug opening in the bottom of
the freezer door, lower the draw handle. Draw off all
the sanitizing solution.
Figure 6-27
Note: On Models 754, 774, 791, and 794,
momentarily pull the center draw handle down to
sanitize the center door spout.
8. Once the sanitizer stops flowing from the door spout,
raise the draw handle and press the WASH button,
canceling the beater motor operation.
Note: You have just sanitized the freezer. Make
sure your hands are sanitized before continuing
these instructions.