Model 338 Specifications
Freezing Cylinder
Two, 2.8 quart (2.7 liter) volume.
Mix Hopper
Two, 20 quart (18.9 liter).
Beater Motor
Two, 1.0 hp.
Refrigeration Unit
One, approximately 9,500 btu/hr compressor. Refrigerant
R404A.
One independent (SHR) compressor, approximately 400
btu/hr. Refrigerant R134a. (BTU's may vary based on
compressor used.)
Electrical
One dedicated connection.
Maximum Minimum
Electrical
Fuse Size Circuit Ampacity
208-230/60/1 Air 35 28
208-230/60/1 Water 35 28
208-230/60/3 Air 25 19
208-230/60/3 Water 25 19
This unit is manufactured in other electrical characteristics.
Refer to the Distributor Data Book for
availability. (For exact electrical information, always refer to
the data label of the unit.)
Air Cooled
Clearance: 6" (15.2 cm.) on both sides. It is recommended to
install a skirt to one side of the unit, and to place the back of
the unit against a wall. This will assure proper air flow across
condensers to obtain optimum performance.
Water Cooled
Water inlet and drain connections under side of base 3/8"
FPT.
Dimensions
Width: 26-7/16" (67.2 cm.)
Depth: 31-3/16" (79.2 cm.)
Height: 38-3/4" (98.4 cm.)
Counter Clearance: 3-1/2" (8.9 cm.) mounted on
standard legs.
Approximate Weights
Net: 465 Ibs. (219.0kgs.) Crated: 542 Ibs. (245.9 kgs.), 29.9
cu. ft. (.84 cu. m.)
Availability and specifications are subject to change
without notice.
This unit is designed and constructed to meet stringent safety
and sanitation requirements for NSF and UL.