EasyManua.ls Logo

Taylor C706 - Electrical Troubleshooting

Taylor C706
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36
Troubleshooting
Models C706 & C707
Electrical Troubleshooting
The following information provides a sequential list of
electrical components that L--1 power travels through
to initiate various operations.
Auto Mode of Operation:
L--1 power travels through the power switch, beater
overload switch, the compressor high pressure
cut--out switch, the overload terminal (OL) on the
power board, the BTR terminal of the power board, and
energizes the coil of the beater motor contactor.
L--1 power travels through the power switch, beater
overload switch, the compressor high pressure
cut--out switch, the overload terminal (OL) on the
power board, the COM terminal of the power board,
and energizes the coil of the compressor contactor .
L--1 power travels through the power switch, beater
overload switch, the compressor high pressure
cut--out switch, the L--1 terminal of the power board,
the MIX terminal of the power board, and energizes the
hopper refrigeration compressor and condenser fan.
Wash Mode of Operation:
L--1 power travels through the power switch, beater
overload switch, the compressor high pressure
cut--out switch, the overload terminal (OL) on the
power board, the BTR terminal of the power board, and
energizes the coil of the beater motor contactor.
Pump Mode of Operation:
L--1 power travels through the power switch, beater
overload switch, the compressor high pressure
cut--out switch, the overload terminal (OL) on the
power board, the PUMP terminal of the power board,
and energizes the coil of the pump motor .