56
MIDI IMPLEMENTATION
Parameter Name CC# Range / Description
Instrument Pan 102 0-127
Instrument Level 103 0-127
Bypass All 114 0-63 Off, 64-127 On
Harmony Hold CC Control 119 0-63 Off, 64-127 On
Global Vibrato 1 0-127
Song Step Forward 115 >63, Song Steps Forward”
Song Step Backward 9 >63, Song Steps Backward”
*S
pecial CC’
s (same for both the Advanced and GM-Basic CC maps)
Pitch Correction Scale Notes 118 MSB 0nnopqrsB (Binary Pattern)
nn reserved
o=1 C note on
p=1 C#/Db note on
q=1 D note on
r=1 D#/Eb note on
s=1 E note on
117 LSB 0tuvwxyzB
t=1 F note on
u=1 F#/Gb note on
v=1 G note on
w=1 G#/Ab note on
x=1 A note on
y=1 A#/Bb note on
z=1 B note on
o...z=0 notes off use 0 value
Example Custom Scale Message:
Intended scale: C, E, G, B based on a C root. This scale may be transposed by changing
the scale root.
Message: CC#118, 00010001 (converts to 17 decimal), CC#117, 00010001
(17 decimal)
MIDI Program Change messages result in a Song Number change while in Song mode.
In any other mode, MIDI Program Change messages result in a Preset Number change.
Note: To capture the desired correction scale you can change the correction scale from the front
panel and record the MIDI out.
Other MIDI messages:
Program Change: Received/Transmitted. In Song mode only received
- changes Song number.
Pitch Bend: Received. Controls Pitch or Gender, assignable in preset.
Note On/Off: Received.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TC-Helicon VoiceLive and is the answer not in the manual?

TC-Helicon VoiceLive Specifications

Analog Inputs IconAnalog Inputs
mic impedance3.6/1.8 kOhm
line impedance21/13 kOhm
line input level at 0 dBFS24 dBu to 0 dBu
Analog Outputs IconAnalog Outputs
output impedance40 Ohm
max output level balanced20 dBu
max output level unbalanced14 dBu
Operating Environment IconOperating Environment
operating temperature32° F to 122° F (0° C to 50° C)
storage temperature-22° F to 167° F (-30° C to 70° C)
humidityMax. 90 % non-condensing
Supplementary IconSupplementary
dimensions11.1" x 10.25" x 3.5" (282 x 260 x 89 mm)
weight5.9 lb. (2.7 kg)
mains voltage100 to 240 VAC, 50 to 60 Hz (auto-select)