TCL Air Conditioner Service Manual
9. Installation manual
9.1 Installation Details
Connecting pipe length
Model
Pipe size(Inch)
Liquid Gas
TAC‐12CHSD/XAB1I TAC-12CHSD/XAB1IHB
1/4 3/8
1/4 3/8
1/4 3/8
1/4 1/2
Mode
Standard length: m
Refrigerant piping
Max. length: m
Additional refrigerant
Calculation: ×g=20g/m(A-5m)
3.0 15 20g/m
3.5 15 20g/m
5.0 15 30g/m
5.0 15 30g/m
Connecting cables
The power cord should be selected according to the following specifications sheet.
ppliance Amps Wire Size
5
WG21/0.75 mm
2
10
WG18
1.0 mm
2
13
WG15 /1. 5 mm
2
18
WG14
1.6 mm
2
25
WG12
2.0 mm
2
30
WG10
2.5 mm
2
Outdoor unit
Indoor unit
Pi pe length is
15 meters Max.