FREQUENCY
RESPONSE
———<——
$$
1.
Place
TEAC
test
tape
YTT-1003
(using
7-1/2ips),
yTT-1002
(Using
3-3/4ips)
on
the
unit.
2.
Compare
the
readings
obtained
on
the
level
meter
with
the
re-
sponse
limits
given
in
Fig.7-3
3.
Forward
and
reverse
playback
frequency
response
should
be
identical.
RESPONSE
iN
dB
[eT
2
i
a
27
50
100
500
1K
5K
10K
50K
FREQUENCY
1N
Hz
M-0288
Fig.
7-3
Frequency
Response
~playback-
HEADPHONE
OUTPUT
CHECK
1.
Place
OUTPUT
controls
at
specified
level
setting
(400
Hz
signal
at
-8
dB).
2.
Connect
an
82
non
inductive
resistor
across
the
headphone
output,
connect
level
meter
across
the
resistor.
3.
Level
meter
should
indicate
-24
dBm
+2
dB.
Fig.
7-4
Headphone
Connecting
Resistor