Flushing technology
6-12
TECE flushing technology – U 1 urinal flush valve
Pre-flush, factory setting o
Pre-flush, setting range .- s
Pause function, factory setting o
Hygiene flush, factory setting o
Hygiene flush, setting range o,  hours,  hours
230 V/12 V mains version
The power supply of the mains version is via a transformer
which converts  V AC to  V DC (order no. ,
order separately).
The electronics have one connection to the transformer
(connector with white marking) and one to an electronic
cartridge (connector with black marking). The third cable is
to earth the electronics onto the flush valve's brass hous-
ing.
Urinal electronics, 230 V/12 V mains version
Up to five urinal electronic units can be powered at the
same time by the transformer. For this reason, the trans-
former is not (!) located in the flush valve's bare-wall
protection system. The transformer fits conveniently in a
standard flush-mounted installation box.
For series installations, the electronics must be connected
in parallel and the connection cable between the trans-
former and the furthest electronic unit can be a maximum
of  m long.
Schematic diagram of a series installation of 5 urinal electronic units
It is recommended that only TECE original products are
used for the installation. Make sure that the polarity is cor-
rect when connecting the cables.
Technical data urinal infrared electronics, 230 V/12 V
mains
Minimum flow pressure . bar
Max. operating pressure  bar
Flow rate at  bar . l/s
Mains voltage  V
Operating voltage  V ( ± %)
Power input  W
Max. power input  W
Protection class III
Safety extra low voltage
(SELV)
Flush time, factory setting  s
Flush time, setting range - s
Pre-flush, factory setting o
Pre-flush, setting range .- s
Pause function, factory setting o
Hygiene flush, factory setting o
Hygiene flush, setting range o,  hours,  hours
Technical data 230 V/12 V mains transformer
Input voltage  V AC (±  %)
Frequency – Hz
Rated Output voltage  V DC (±  %)
Output voltage tolerance ± %
Residual ripple <  mVpp
Rated Output current . A
Nominal power  W
Minimum load
Energy eciency  %
Overload protection electronic
Short circuit protection electronic
Type of protection IP 