EasyManua.ls Logo

TECE U2 TECEfilo - Converting the A1 Drain Valve to the A2 Drain Valve; F 10 Filling Valve

Default Icon
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Flushing technology
6-6
TECE flushing technology – cistern
Converting the A1 drain valve to the A2 drain
valve
If a drain valve is replaced as a spare part or the new
drain valve is modified because of the additional functions
(./. litre flush, throttle set), the new A drain valve
oers full compatibility with the old A version.
The operating lever, throttles and valve seat are included
in the scope of delivery along with the A drain valve.
36 mm
42 mm
Conversion set 9820223, scope of delivery
The TECE cistern drain valve can be replaced easily.
The old A drain valve should be disposed of, together
with the associated valve seat and seal.
When replacing an old A drain valve with a new A one,
care must be taken to ensure that the operating lever is
also replaced.
F 10 filling valve
The F  replacement filling valve (order number
) universally fits in all TECE cisterns and in many
competing cisterns.
F 10 filling valve
Properties:
Low-noise in accordance with acoustic group  (DIN
)
Functional range:  hPa to , hPa
Minimum flow pressure:  hPa
Adjustable fill level
Compact design
Adjustable outlet pipe