TECH
20
The following screenshot presents daily settings of
program no. 7 for Monday
24⁰⁰-01⁵⁹- economical temperature
02⁰⁰-06⁵⁹- comfort temperature
07⁰⁰-14⁵⁹- economical temperature
15⁰⁰-21⁵⁹- comfort temperature
22⁰⁰-00⁵⁹- economical temperature
NOTE
When the user finishes the editing process by pressing MENU button, the controller
returns to the main screen view and this program is selected as the current program.
VII.c.9) Pre-set comfort temperature
Pre-set comfort temperature is used in weekly
control mode and day/night mode. Press or
button until the comfort temperature change panel
appears on the screen.
Press + or - to set the desired temperature.
Press to confirm and move on to the next
parameter or press and hold MENU to confirm and
return to the main screen view.
VII.c.10) Pre-set economical temperature
Pre-set economical temperature is used in weekly
control mode and day/night mode. Press or
button until the economical temperature change
panel appears on the screen.
Press + or - to set the desired temperature.
Press to confirm and move on to the next
parameter or press and hold MENU to confirm and
return to the main screen view.
VII.c.11) Pre-set temperature hysteresis
Room temperature hysteresis defines the pre-set
temperature tolerance in order to prevent undesired
oscillation in case of small temperature fluctuation
(within the range of 0,2 ÷ 4°C).
Example:
Pre-set temperature : 23°C
Hysteresis : 1°C
The room regulator reports that the temperature is
too low only when the room temperature drops to
22 °C.
In order to set the hysteresis, press or until the hysteresis setting appears on the screen.
Use + or - to set the desired hysteresis value. Press to confirm and move on to the next
parameter or press and hold MENU to confirm and return to the main screen view.