TECH
10
V.b) Operation modes
The user has three operation modes to choose from:
Day/night mode
In this mode the pre-set temperature value depends on the current time of the day. The user may
set different temperature values for the daytime and nighttime (comfort temperature and
economical temperature) as well as define the exact time of entering day mode and night mode.
In order to activate this mode, press button until day/night mode icon appears on the main
screen.
Weekly control
This mode enables the user to define the time when the pre-set comfort temperature and the pre-
set economical temperature will apply. The user may set 9 different programs divided into three
groups:
- programs 1÷3 – daily temperature values are set for all days of the week;
- programs 4÷6 – daily temperature values are set separately for the weekdays (Monday-Friday)
and for the weekend (Saturday-Sunday);
- programs 7÷9 – daily temperature values are set for each day of the week separately.
* The display shows the hours when the comfort temperature applies. In the remaining time
period economical temperature applies.
In order to activate this mode press and hold until the weekly control icon appears on the
main screen.