7.3.2 F61
TOP PREVIOUS NEXT
l
Problem or condition
When the power switch is switched on, it automatically switches back off, making it
impossible to switch power on.
l
Correction procedure
Faulty Tuner/Amplifier (SA-DV250) output IC (IC601).
(When a DC voltage is applied to speaker terminals.)
@
TOP PREVIOUS NEXT