Page #8 background image
Servo
P.C.B.
.
Remove
the
3
screws
@~®).
.
Unsolder
the
2
terminals
of
spindle
motor.
.
Remove
the
FPC
board
from
the
optical
pickup.
Caution:
To
prevent
the
breakdown
of
the
laser
diode,
antistatic
shorting
pin
is
inserted
into
the
FPC
board.
B.
Loading
motor
P.C.B.
1.
Remove
the
2
screws
@,
©).
2.
Unsolder
the
2
terminals
of
loading
motor.
Procedure
12-13-15
.
Remove
the
drive
belt.
.
Remove
the
2
screws
@,
@).
.
Release
the
2
claws.
.
Unsolder
the
2
terminals
of
the
lead
wire
of
loading
motor.
SL-P999
SL-P999
Mi
MEASUREMENTS
AND
ADJUSTMENTS
Caution:
¢
It
is
very
dangerous
to
look
at
or
touch
the
laser
beam.
Loading
motor!
Spindle
motor
FPC
board
terminals
Refer
to
the
handling
precautions
for
optional
pickup
and
instructions
for
traverse
oll
(See
page
9).
1.
Remove
the
2
screws
@,
@)
2.
Unsolder
the
2
terminals
and
the
2
screws
(@,
Q).
Optical
pickup
ong
sien
2
2
)y
Unsolder
Brush
terminal
Caution:
Take
care
not
to
touch
the
brush
.
Set
the
power
switch
in
the
“OFF”
position.
.
Remove
the
power
switch
rod
by
using
a
screwdriver.
Procedure
.
Power
supply
P.C.B.
10-12-16
.
Remove
the
2
screws
@,
@).
.
Release
the
flat
cable
(CN12).
<
Qe
terminal.
(Laser
radiation
is
invisible.)
With
the
unit
turned
“on”,
laser
radiation
is
emitted
from
the
pickup
lens.
Avoid
exposure
to
the
laser
beam,
especially
when
performing
adjustments.
PREPARATION
1.
Remove
the
cabinet
(see
Ref.
No.
1
of
the
disassembly
instructions).
2.
Remove
the
disc
clamper
and
magnet
(see
Ref.
No.
2
and
No.
11
of
the
same).
3.
Remove
the
disc
holder
and
power
switch
rod
(see
Ref.
No.
3
and
No.
16
of
the
same).
4.
Place
the
test
disc
and
magnet
on
the
turntable.
5.
While
holding
the
Open/Close
switches
(S101,
$102)
in
the
directions
indicated
by
the
arrows,
switch
the
player
power
ON.
6.
After
the
test
disc
starts
rotating,
release
the
Open/Close
switch
(S101,
$102).
ADJUSTMENT
POINTS
©
Servo
P.C.B.
VR106
aeeeres
VR101
Q
Pe
VR105
a
5
VR104
3
TS
<>
|e
Nee
®
:
WZ
gy
Bi
ULL!)
FEG
g
4
,
1)
iaae)
=
=
evi,
4
NS
ie
NZ
VR102
GNO
Hw
v
RF
output
BE
alll
Adjusting
fixture
g,
connector
(Focus
offset
(Focus
gain
/
(Tracking
offset
adj.)
adj.)
adj.)
ey
(GND)
(Tracking
(Tracking
gain
adj.)
balance
adj.)
(Best
eye
adj.)
Test
disc
Magnet
+
¢
Main
P.C.B.
(OPTICAL)
(L)(R)
Offset
voltage
adj.
ie
offset
voltage
adj
A
IC80l
1IC803
IC802
!C804
Ne
760)
ae
en
@(+9Vv)
012
(Connect
the
red
lead
wire
of
servo
gain
adjuster.)
@(-9Vv)
(Connect
the
blue
lead
wire
of
servo
gain
adjuster.)
¢
Temporary
setting
of
each
VR
MageaS
Temporary
VR
setting
if
any
of
the
trimmer
VRs
are
replaced
or
require
readjustment,
temporarily
set
them
to
the
following
positions.

Other manuals for Technics SL-P999

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Technics SL-P999 and is the answer not in the manual?

Technics SL-P999 Specifications

General IconGeneral
BrandTechnics
ModelSL-P999
CategoryCD Player
LanguageEnglish

Related product manuals