To bring the point close to the part, follow the foot adjustment procedure below:
Loosen the screws until the foot slides (4 hex spanner).
Position the foot at the desired distance (L).
1 : Screws
2 : Supporting leg
3 : Tooling plate
(example: 2 mm (0.079 in)
thickness)
4 : Non-slip surface
5 : Slide gauge: depth gauge