Do you have a question about the Technogym BIOCIRCUIT and is the answer not in the manual?
Provides informative notes and classification of safety signs according to potential hazards.
Explains network installation costs and the dependency of equipment operation on technical characteristics.
Emphasizes collaboration with technicians and Technogym's non-responsibility for incorrect site preparation.
Customer must inform Technogym about component installation and operational status before setup.
Equipment of BIOSTRENGTH LINE may be fitted with UNITY MINI Display and 10" Display.
Discusses non-Biocircuit Free cardio machines and the optional Unity Self display.
Details the UNITY Display used on RUN, BIKE, NEW SYNCHRO machines and UNITY SELF.
Provides power supply and maximum absorption values for various equipment models.
Mandatory RCD Switch Type F required for every strength machine.
Ensures electrical system compliance and proper installation and earthing of sockets.
Illustrates the location of product sockets on different machine types (front/back).
Prohibits mixed wired and wireless connections for Biocircuit equipment.
BIOCIRCUIT requires a dedicated network, preferably wired.
Illustrates a recommended wired network setup for Biocircuit.
Illustrates a recommended wireless network setup for Biocircuit.
Illustrates a mandatory complex network setup for Biocircuit.
Shows a forbidden network setup causing local network latency.
Shows another forbidden network setup causing local network latency.
Recommends a router with 4G failover for unstable internet connections.
Details general network requirements for Biocircuit and Biocircuit Free.
Specifies requirements for Ethernet cabled networks, including cable type and switch ports.
Outlines requirements for wireless network installation and configuration.
Specifies firewall/router rules for Mywellness Cloud, including open ports and DNS names.
States that proxy is not managed.
Illustrates minimum infrastructure requirements for network bandwidth based on the number of equipment.
UNITY SELF must be connected via Ethernet cable and requires a static IP address.
Section for acknowledging and accepting the document's content.
First released version of the manual.
Details changes made in Revision 2.0, including circuit breakers and network configuration.
Details changes made in Revision 3.0, concerning broadcast network, access points, and Wi-Fi settings.
Details changes made in Revision 4.0, including technical data and network architecture.
Details changes in Revision 5.0, including scope extension and RCD switch recommendation.
Details changes in Revision 6.0, specifically disabling Wi-Fi Auto Channel.