8 TROUBLESHOOTING
The motor is stopped and the
electrical panel is switched off.
Verify that the power cord is connected
and intact.
The thermal protiction internal of
the motor have been activaded.
Unplug the unit, wait an hour before
connecting again, verify the functioning.
If not working change the motor.
Emergency button pressed.
Release the button by turning; then
press the start button.
The electrical panel is not
working in all or in some of the
buttons.
Possibile tension overload.
Remove the power plug, wait a few
minutes before reinsert the plug and
operate the equipment.
Failure on the electrical panel.
Replace the electrical panel.
The motor is turning but does
not transmit the rotation to the
vertical shaft.
Feather key missing or broken on
the reducer shaft.
Replace /insert the feather key.
Transmission joint broken or
unhooked.
Verify the connection between the
various joints.
Machine not correctly positioned.
The feets are not adjusted
correctly.
The panel is on, but the motor
is not working.
For any other kind of issues or doubts, please, contact the Customer Service Dep. in Tecmec