EasyManua.ls Logo

Tecnam P2008 JC - Cabin Fire;Electrical Smoke in Cabin During Flight; Electrical Smoke;Fire in Cabin on the Ground; Engine Fire In-Flight

Tecnam P2008 JC
264 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 3 - 16
Ed. 1, Rev. 0
Section 3 Emergency procedures
SMOKE AND FIRE
7.3. ENGINE FIRE IN-FLIGHT
1. Cabin heat: OFF
2. Fuel selector valve: OFF
3. Electric fuel pump: OFF
4. Throttle: FULL FORWARD until the engine stops
5. Ignition key: OFF
6. Cabin vents: OPEN
WARNING
Do not attempt engine restart
7. Land as soon as possible applying forced landing procedure(See Para. 7).
7.4. CABIN FIRE / ELECTRICAL SMOKE IN CABIN DURING FLIGHT
1. Cabin heating: OFF
2. Cabin vents: OPEN
3. Try to choke the fire. Direct the fire extinguisher towards flame base
If smoke persists:
4. Alternator& Master switches: OFF
5. Land as soon as possible and evacuate the aircraft
CAUTION
If the MASTER SWITCH is set to OFF, consider that flaps ex-
tension and pitch trim operation is prevented.
7.5. ELECTRICAL SMOKE/FIRE IN CABIN ON THE GROUND
1. Generator switch: OFF
2. Throttle Lever: IDLE
3. Ignition key: ALL OFF
4. Fuel Selector Valve: OFF
5. Master Switch: OFF
6. Aircraft Evacuation carry out immediately