EasyManua.ls Logo

TECNICOMAR MINIMAR PLUS - Technical characteristics and spare parts; 9.1 Electrophysical characteristics; 9.2 A typical analysis of produced water

TECNICOMAR MINIMAR PLUS
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Instructions for the installation, use and maintenance of Tecnicomar watermaker
9-33
9 Technical characteristics and spare parts
9.1 Electrophysical characteristics
TYPE (GpD)
(1)(1)
Max. power
rating (A)(±1A)
Operating voltage
(V)
Production with
new membranes
(2)
(liters per hour
15%)
Noise at 1 m
distance
(dBA)
MINIMAR 200-400-600 PL
6
230 V/ 50 Hz
35-70-120
79.5
SAILOR 200 S 1/21
9
230 V/50 Hz
35 - 60
79.5
SAILOR 400 S 2/21
9
230 V/50 Hz
70 100
79.5
SAILOR 600 S 3/21
12
230 V/50 Hz
100 - 160
79.5
SAILOR 1000 S 2/40
13
230 V/50 Hz
160 - 250
79.5
SAILOR 1500 - S 3/40
13
6
230 V/50 Hz
400 V/50 Hz
220 350
220 - 350
79.5
SAILOR 2000
14
7
230 V/50 Hz
400V/50Hz
300
300
79.5
See test certificate for other details (i.e. different voltages, etc…)
9.2 A typical analysis of produced water
Component
Raw water
Desalinated water
Ammonia (mg/l)
no traces
no traces
Bicarbonate (mg/l)
63
4.9
Boron (mg/l)
4.0
0.4
Bromide (mg/l)
85
0.85
Calcium (mg/l)
315
0.8
Carbonate (mg/l)
no traces
no traces
Chloride (mg/l)
17600
183
Fluoride (mg/l)
0.8
< 0.1
Hydroxide (mg/l)
no traces
no traces
Iron (mg/l)
0.3
< 0.1
Magnesium (mg/l)
1300
2.6
Manganese (mg/l)
< 0.1
< 0.1
Nitrate (mg/l)
< 2.0
< 2.0
Potassium (mg/l)
418
6.4
Silicon as Si02 (mg/l)
10.7
< 5.0
Sodium (mg/l)
11000
105
Strontium (mg/l)
13.8
0.4
Sulfate (mg/l)
2436
2.3
Total sulfides (mg/l)
< 0.1
< 0.1
Turbidity (FTU2)
0.28
0.13
Conductivity (mhs/cm)
45000
550
Hardness as CaCO3 (mg/l)
6140
28
P-Alcalinity as CaCO3 (mg/l)
0
0
T-Alcalinity as CaCO3 (mg/l)
104
8
pH (units)
7.7
7.4
TDS at 180 oC (mg/l)
36073
250
(1)
Nominal production expressed in gallons per day.
(
1
)
Only for special series (No. of membranes/membranes type)
(2)
Test condition:
1. Operating pressure 60 BAR (850psi)
2. prefilter feed pressure 1.8 BAR (26psi)
3. feed water temperature 20C
4. feed water salinity 36000 ppm
5. feed water pH-value 3-11.

Table of Contents