DISPLAY TEST INDICATIONS
DISPLAY
TEST
SIGNIFICATO
OFF Exnguishing phase in progress, lasng about 10 minutes
AC First-stage stove ignion, bioethanol loading and waing for ame ignion
AR second stage ignion stove, ame enrichment.
PA Step followings ignion phases
PH Phase heang stove
P1-P2-P3 Power level set
10...30°C Degree desidered temperature in the stove room
SF Stop Flame: Operaon block for likely bioethanol depleon
CP-TS-PA Control menu available exclusively for CATs
(Technical Support Center)
AF Ignion failure: ignion failure block
H1....H7 Allarm system, the number idenes the alarm causes
Bat1 Finished clock baery (type CR2032)
When the stove is in stand by mode, it visualizes on display OFF
if the stove is in MANUAL or AUTOMATIC mode.
On display it visualizes the text AC (a); overcamed some control cycles and following when the ignion
occours, on the display it visualize the text AR (heang ignion), this phase will last for some minutes it
allowing the correct ignion and heang of the heater exchange.
Aer a few minutes, the heater will go o during the cleaning phase PA, following on heang phase will be
on display PH and following in work phase, indicang the selected power in case of manual operaon,
or indicang the selected temperature in the case of automac operaon.
6. IGNITION/FUNCTIONING/ PROGRAMMING
On stand-by stove press the ON/ OFF buon and start the ignion procedure.
Posion the switch C in posion ON,