EasyManua.ls Logo

Tecno Air System RUBY COMPACT - Ignition and Operation Modes Part 2; Shutdown Procedure; Manual Operation Mode; Automatic Operation Mode

Tecno Air System RUBY COMPACT
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TECNO AIR SYSTEM
Essege Grouppag. 31 di 40
SHUTDOWN
Pressing the ON/OFF buon while the stove is lit it start the shutdown phases which it will provide:
a) Interrupon of fuel load.
b) Exhauson of the fuel present in the burner while keeping the fun working.
c) Cooling the body stove while keeping the fan working (usually x 10’)
d) The “OFF” indicaon on the display with the missing minutes at the end of the shutdown
During the switch o phase, it will not be possible to switch on the stove again, aer switching on the
system, it automacally switches back to standby mode.
MANUAL FUNCTION
In the manual funcon mode it set the power to make the stove work, regardless of the room temperature
in which it is installed.
To select the MANUAL mode press the buon set.
For example to set on the display P2 (power 2)
It is possible to increase the power pressing the buon +
Or for decrease pressing the buon -
AUTOMATIC FUNCTION
In the AUTOMATIC operang mode it can set the wished temperature where the stove it placed.
The stove, automacally, modulates the powers in funcon of dierences between the wished
temperature (on the display) and the temperature detected by the probe; when the desidered
temperature is reached the stove will work at the minimum power taking on power 1 (minimum power).
To select the AUTOMATIC mode press the buon set .
Set on the display example 20°C .
It is possible to increase the wished temperature pressing the buon +
or it decrease pressing the buon -
In AUTOMATIC mode
The display shows alternately, the desidered temperature
and the power automacally selected by the modulang system