TECNO AIR SYSTEM
Essege Grouppag. 34 di 40
ALARM LIST
Testo
display
utente
Alarm descripon Alarm log
(CAT)
FULL
LOSS
Load interrupon for burner too full. The FULL signal occurs when the
tank is completely lled. The stove will emit a sound signal along with
the word FULL, obviously this only happens if the stove is powered. If the
user lls the bioethanol full with a disconnected plug, the unit will emit
a sound when it is switched on because it is full and the word FULL will
appear.
This signal warns that there is a bioethanol spill that can be caused by
the user’s tapping, but also in the unlikely event of a tank or pump leak.
Since alcohol evaporates in a short me, the content in the collecng
pan with its display status disappears aer a period of me, whereas if
there is a leak, tank, pump, or tube Of the connecon, the user is then
noed of the anomaly. If the problem persists, contact your authorized
service center.
TILT Operaon block for an-fallen stove sensor operaon. Check the correct
posioning of the stove. If the problem persists, contact your qualied
service center.
SF Flame Stop (if the thermocouple detects a temperature lower than a
set value, interpreng this as a ame-out). Repeat the ignion. If the
problem persists, contact your authorized service center.
H3
AF Ignion failure (if a ame does not appear in a 15 minute me or the
start temperature is not reached). Repeat the ignion, if an error occurs,
contact your authorized service center.
H4
H5 Black out: power o for power failure. Reset the power supply, restart
the ignion, if the problem persists, contact your authorized service
center
H5
H6 Thermocouple faulty or disconnected.
Contact your authorized service center.
H6
H7 Temperature abnormality
(Switch o at excessive temperature)
Fully cool the stove, restart the ignion, if the problem persists contact
the authorized service center
H7
Bat1 Baery clock nished (type CR2032)
Contact the service center
-