7.1.2. PROGRAMMING MENU
Press the key for more than 5 seconds to access the “Programming” menu. A “PA1” access PASSWORD will be
requested if required.
When accessed, the display will show the first parameter ("diF").
Use keys and to scroll through all the parameters of the Programming menu:
Select the desired parameter using the and keys. Press the key to display the current parameter value. Use the
and keys to change their value and press the key to store the value.
Note: It is recommended to switch the instrument off and on again each time the parameter configuration is changed to prevent
malfunctions on the configuration and/or timings in progress.
7.1.3. SETPOINT MODIFICATION BLOCK
The instrument provides the option to disable keyboard operation.
The keyboard can be locked by programming the “LOC” parameter.
If the keyboard is locked, it is always possible to access the “Machine Status” menu by pressing the key and display the
Setpoint, however its value cannot be changed.
To unlock the keyboard repeat the procedure used to lock it.
7.1.4. PASSWORD
The password “PA1” grants access to level 1 parameters (User) while the password “PA2” grants access to level 2 parameters
(Installer).
Level 2 parameters also contain all level 1 parameters.
In the standard configuration the password “PA1” is not enabled (value = 0) while password “PA2” is (value = 15). To enable
the password “PA1” (value ≠ 0) and assign it the desired value, enter the “Programming” menu, select the “PS1” parameter with
the and keys, press the key, set the desired value and confirm it by pressing the key again.
If the password "PA1" is enabled, when entering the “Programming” menu, you will be asked to enter the password “PA1” or
“PA2” based on the parameters you wish to change. To enter the password ‘PA1’ (or ‘PA2’):
If the password entered is wrong, the instrument will display the 'PA1' (or 'PA2') label and the entry procedure must be
repeated. Level 2 parameters can also be accessed from level 1 parameters, by selecting the 'PA2' parameter (present at level
1) with the keys and and then pressing the key .