Group 12: Monitoring Parameters
Code
Parameter
Name
Setting Range
Default
Attrib
ute
hours.
12-54
Frequency
Command of
Previous Fault
Display
frequency
command of
previous fault
-
12-55
Output
Frequency of
Previous Fault
Display output
frequency of
previous fault
-
12-56
Output Current
of Previous
Fault
Display output
current of
previous fault
-
12-57
Output Voltage
of Previous
Fault
Display output
voltage of
previous fault
-
12-58
DC Voltage of
Previous Fault
Display DC
voltage of
previous fault
-
12-59
DIO Status of
Previous Fault
Display DI/DO
status of
previous fault
Description is
similar to 12-05
-
12-60
Inverter Status
of Previous
Fault
Display inverter
status of
previous fault
Description is
similar to 12-43
-
12-61
Trip Time 1 of
Last Fault
Display the
operation time
of last time’s
fault, 12-62 is
the days, while
12-61 is the
remaining
hours.
-
12-62
Trip Time 2 of
Last Fault
-
12-63
Recent
Warning
Messages
Display the
recent warning
messages
-
12-64
Previous
Warning
Message
Display the
previous
warning
message
-
12-65
Motor Start
Angle
0~360 -
12-66 Encoder Angle 0~360 -
12-67
Cumulative
Energy (KWHr)
0.0 ~ 999.9
12-68
Cumulative
Energy (MWHr)
0 ~ 60000
12-69
~
12-71
Reserved
12-72 RTC Date
12.01.01 ~
99.12.31
12.01.0
1
Note8
12-73 RTC Time
00:00 ~ 23:59
00:00 Note8
12-76
No-Load
Voltage Output
0.0~600.0 -
12-77 Reserved
12-78 Z-Phase Bias -9999~9999 -
Group 12: Monitoring Parameters
Code
Parameter
Name
Setting Range
Default
Attrib
ute
Value
12-79
Pulse Input
Percentage
0.0~100.0 -
12-80
AI1 Frequency
Command
0.0~599.0 0 Note2
12-81 Reserved
12-82 Motor Load 0~200.0 - Note4
12-85 AI3 Input
Display the
current Al3 input
(-10V
corresponds to -
100%, 10V
corresponds to
100%)
- *10
*: Refer to the attachment 1 in our instruction
manual.
** A510s 200V 50HP (and the above) and 400V
100HP (and the above) don’t support heatsink
temperature display function.
Group 13: Maintenance Parameters
Code
Parameter
Name
Setting Range Default
Attrib
ute
13-00
Inverter
Capacity
Selection
---- - *4
13-01
Software
Version
0.00-9.99 - *4
13-02
Clear
Cumulative
Operation
Hours
0: Disable to
Clear
Cumulative
Operation
Hours
0 *1
1: Clear
Cumulative
Operation
Hours
13-03
Cumulative
Operation
Hours 1
0~23 - *4
13-04
Cumulative
Operation
Hours 2
0~65534
(Note4)
- *4
13-05
Selection of
Cumulative
Operation Time
0: Cumulative
time in power
on
0 *1
1: Cumulative
time in
operation
13-06
Parameters
Locked
0: Parameters
are read-only
except 13-06
and main
frequency
2 *1
1 : User
defined
parameters