3-54
The following table shows maximum output frequency for each control mode.
Duty Cycle Control mode Other settings Maximum output frequency
Heavy Duty
(00-27=0)
V/F
V/F + PG
SLV2
maximum frequency set to
599Hz
599Hz
SLV
200V 1~10HP, 400V 1~15HP 150Hz
200V 15~25HP, 400V 20HP 110Hz
400V 25~30HP 100Hz
200V 30~100HP,
400V 40~215HP,
carrier (11-01) is set as 8K or
below 8K
100Hz
200V 125~150HP,
400V 220~425HP,
carrier (11-01) is set as 5K or
below 5K
200V 30~100HP,
400V 40~175HP,
carrier (11-01) is above 8K
80Hz
SV unlimited 599Hz
PMSV unlimited
Twice of Base frequency
PMSLV unlimited
599Hz
Normal Duty
(00-27=1)
V/F
V/F + PG
maximum frequency set to
120Hz
120Hz
SLV /SV
PMSV/ PMSLV
SLV2
No normal duty mode
-