35
LED display Possible solutions
EF4
External Fault
(S4)
EF5
External Fault
(S5)
EF6
External Fault
(S6)
CF07
Motor control
fault
Perform rotational or
stationary auto-tune
Increase minimum output
frequency (01-08)
CF08
Motor control
fault
Increase the value of 22-10
and 22-23 properly.
Re auto-tune (22-21)
Check if the load is too
heavy to raise torque output
limit.
CF00
Operator
Communication
Error
Disconnect the operator and
then reconnect.
Replace the control board
CF01
Operator
Communication
Error 2
Disconnect the operator and
then reconnect.
Replace the control board
OPR
Disconnection
Check the keypad operator
connection
FBLSS
PID Feedback
Signal Loss
Check if the proportion of
loss pressure (23-19) is set
correctly
Make sure the feedback
sensor is installed correctly
and PID feedback signal
operates normally.
SC
Short circuit
Check the motor wiring.
Disconnect motor and try
running inverter.
run
Motor1/Motor2
Switch
Improve the control
sequence, motor can be
switched in stop.
LED display Possible solutions
LPBFT
Low Pressure
Fault
Check feedback signal is
correct and with connection.
Check if feedback value of
pressure is lower than limit of
minimum pressure (23-15)
OPBFT
High Pressure
Fault
Check feedback signal is
correct and with connection.
Check if feedback value of
pressure is lower than limit of
minimum pressure (23-12)
PF
Protection Error
Remove the digital input or
communication run
command.
TOL
External
Overload
Check the reason of external
fault.
Reset the digital input
terminal of external overload.
FB(flash)
PID Feedback
Loss
Check feedback wiring.
Replace feedabck sensor
Table 4.1.2 warning / self-diagnosis and
corrective actions
LED display
Possible solutions
OV
(flash)
Over voltage
Increase deceleration time
Reduce input voltage to
comply with the input
voltage requirements or
install an AC line reactor to
lower the input voltage.
Adjust speed search
parameters.
UV
(flash)
under voltage
Check the input voltage.
Check input wiring.
Replace control board or
complete inverter.
OH1
Heatsink
overheat
Install fan or AC to cool
surroundings.
Replace cooling fan.
Reduce carrier frequency.
Reduce load / Measure
output current
OH3 (flash)
Motor over
Heating
warning
Multi-function input function
set incorrectly.
Check wiring