50
Group 12: Monitoring Parameters
Code
Parameter
Name
Setting Range Default
Attrib
ute
12-03
Line Speed
Display (LED)
0~60000
1500/
1800
*6
12-04
Modes of Line
Speed Display
(LED)
0: Display
Inverter Output
Frequency
0
*1
*6
1: Display Line
Speed with
integer (xxxxx)
2: Display Line
Speed with the
First Decimal
Place (xxxx.x)
3: Display Line
Speed with the
Second
Decimal Place
(xxx.xx)
4: Display Line
Speed with the
Third Decimal
Place (xx.xxx)
12-05
Status Display
of Digital Input
& Output
Terminal (LED /
LCD)
LED display is
shown as
below
no input
corresponden
ces to input
and output
S1 S2 S3 S4S5 S6
S7
RY1 DO1
DO2
PLC
LCD display is
shown as
below
0000 0000
Input Terminal(S7)
Input Terminal(S6)
Input Terminal(S5)
Input Terminal(S4)
Input Terminal(S3)
Input Terminal(S2)
Input Terminal(S1)
0OPEN
1CLOSE
000
Output Terminal(DO2)
Output Terminal(DO1)
Output Terminal(RY1)
0
Output Terminal(PLC)
-
12-06
~
12-10
Reserved
12-11
Output Current
of Current Fault
Display the
output current
of current fault
-
Group 12: Monitoring Parameters
Code
Parameter
Name
Setting Range Default
Attrib
ute
12-12
Output Voltage
of Current Fault
Display the
output voltage
of current fault
-
12-13
Output
Frequency of
Current Fault
Display the
output
frequency of
current fault
-
12-14
DC Voltage of
Current Fault
Display the DC
voltage of
current fault
-
12-15
Frequency
Command of
Current Fault
Display the
frequency
command of
current fault
-
12-16
Frequency
Command
If LED enters
this parameter,
it only allows
monitoring
frequency
command.
-
12-17
Output
Frequency
Display the
current output
frequency
-
12-18 Output Current
Display the
current output
current
-
12-19 Output Voltage
Display the
current output
voltage
-
12-20
DC Voltage
(Vdc)
Display the
current DC
voltage
-
12-21
Output Power
(kw)
Display the
current output
power
-
12-22
Motor’s
Rotation Speed
(rpm)
Display motor’s
current rotation
speed
in VF/SLV
mode
Motor’s rotation
speed =
output
frequency
x(120/motor’s
pole number)
In PG/SV
mode, motor’s
rotation speed
is calculated by
feedback
frequency.
Max limit is
65535
-
12-23
Output Power
Factor (Pfo)
Display the
current output
power factor
-
12-24 Control Mode
Display control
mode
-

Related product manuals