68
LED display Corrective action
(flash)
External
baseblock
bb5
(flash)
External
baseblock
Multi-function input
function set incorrectly.
Check wiring
bb6
(flash)
External
baseblock
bb7
(flash)
External
baseblock
bb8
(flash)
External
baseblock
OS
(flash)
Motor over
speed
Check ASR parameters
group 21.
Check PG parameters
Check overspeed
parameters 20-20/20-
12.
PGO
(flash)
PG open
circuit
Check PG wiring.
Check PG power-
supply.
Make sure brake is
released.
DEV
(flash)
Speed
deviation
Check load
Make sure brake is
released.
Check PG wiring.
LED display Corrective action
Check PG parameters
20-23/20-24.
Increase Acceleration /
deceleration time.
OL1
Motor overload
Check V/f curve.
Check motor rated
current
Check and reduce
motor load, check and
operation duty cycle.
OL2
Inverter
overload
Check V/f curve.
Replace inverter with
larger rating.
Check and reduce
motor load, check and
operation duty cycle.
CE
(flash)
communication
error
Check connection
Check host computer /
software.
CLA
over current
protection level
A
Check load and duty
cycle operation.
CLB
over current
protection level
B
Check load and duty
cycle operation.
Retry
(flash)
retry
Warning disappears
after automatic reset.
ES
(flash)
External
emergency
stop
Turn off run command,
and remove external
emergency stop
command.
EF1 ( flash )
External fault
(S1)
Multi-function input
function set incorrectly.
Check wiring