FM50(TW/ E2)- START GUIDE 4
Check/ verify and change parameters
Check / verify and change parameters for remote start &
remote frequency as necessary before you proceed.
Parameters F10 & F11
See “Basic quick start parameter list” & “How to
chan
g
e
p
arameters
.
RUN using remote speed reference. (Potentiometer, 0-
10Vdc or 4-20mA)
1) To Run. Activate the remote run switch connected to terminals
3&5.
The frequency will ram up to the Frequency set on the pot or
Analog signal (0-10Vdc/ 4-20mA) and according to the set Acc.
time.
2) To Stop. De-activate the remote run switch.
The frequency will ramp down to zero and according to Dec. time.
How to Change Parameters
1) To change parameters: Press the DSP/FUN key, until the first
parameter F00 is displayed.
2) Then use the arrow keys ▲▼to select a parameter then Press
DATA/ENTER key to read the current value.
3) Use the keys to change the setting of the parameters as per basic
quick start parameter list.
Note: For full parameter list refer to the instruction manual.
4) To save each parameter changed, press DATA/ENTER key then