FM50(TW/ E2)- START GUIDE 6
Basic Quick Start Parameter List
Parameter Function Description Range Default setting
F01
Acceleration time in Seconds
0.1 ~ 999 S 05.0
F02
Deceleration time in Seconds
0.1 ~ 999 S 05.0
F03
Remote Start Control Mode
000= Forward / Stop, Reverse / Stop
001= Run/ Stop, Forward / Reverse
0 ~ 1 000
F04
Motor Rotate Direction
000= Forward 001= Reverse
0 ~ 1 000
F06
Max. Frequency limit, see parameter F25 1.0 ~ 200Hz 050/060
F07
Min. Frequency limit 0.0 ~ 200Hz 00.0
F10
Start Mode
000= Keypad 001= Remote(Terminal)
0 ~ 1 000
F11
Speed Reference Source(Frequency)
000= Keypad
001= Remote 0~10v / 0~20mA
002= Remote 4~20mA
0 ~ 2 000
F14
Stop Mode
000= Deceleration stop
001= Free run to stop
0 ~ 1 000
F18
Motor Overload Protection %
F18= Motor rated current/ Inverter rated current
50 ~ 200% 100
F25
Set System to default
010: 50Hz system
020: 60Hz system
010/ 020 000
Note:
1. For Full Parameter List see the Instruction manual, this can be downloaded at
TECO Australia Ltd. Website http://www.teco.com.au
2. The Parameter with blue color is frequently used.